996 Turbo diagnostic manual — Turbo applicability only / PAGE 385
80-14Fault code 28 · Footwell/defrost flap motor - No reaction to activation,
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
911 Turbo (996) Air conditioning H01, H02 80
80-14Fault code 28
Footwell/defrost flap motor - No reaction to activation,
signal unclear
Diagnostic conditions
• Ignition on
Note!
♦No control module fault stored
♦No fault with supply voltage (5 V)
Possible cause of fault
♦Short circuit to voltage/ground or open circuit in the wiring
between the air-conditioning system regulator and the footwell/
defrost flap
♦Servo motor for footwell/defrost flap faulty or flap does not
open/close smoothly.
Affected terminals
Plug B, terminals 3, 9 and 20
Plug D, terminals 3 and 11
Diagnosis/troubleshooting
Work instruction Display OK If not OK
1 Visual inspection ♦Switch off ignition Check the connec- Clean connector or
tor for corrosion plug in correctly ♦Remove the plug for the foot-
and that it is cor- → End well/defrost flap
rectly inserted
⇒ Step 2
2 Check 5 V - supply line to ♦Switch on ignition approx. 5 V ⇒ Step 6
footwell/defrost flap ⇒ Step 3 ♦Measure voltage at plug of the
motor footwell/defrost flap motor
between pin 3 and ground
♦Measure voltage at plug of the
footwell/defrost flap motor
between pin 3 and pin 1
8001 Fault code 28 80-14 page 1
Printed in Germany – 15, 2001 28xxxh02