996 Turbo diagnostic manual — Turbo applicability only / PAGE 412
90-5Control module function · The occurence of particular system errors is stored in the event
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
911 Turbo (996) Instrument cluster K20 90
90-5Control module function
Events
Note!
The occurence of particular system errors is stored in the event
memory. Furthermore, it is possible to read out the time of the
occurence by means of the F8 key. The time is shown in minutes.
The events stored in the event memory concern components of the
instrument cluster and also components of other control modules
like PSM or DME. The following sytem errors are stored in the event
memory:
Note!
During diagnosis, ABS failure and PSM failure events are entered
into the event memory via communication with the PST2 and the
respective warning lights are activated during the automatic control
module search. In this case, no fault is present and the event mem-
ory is to be erased after completion of the diagnosis.
Tester display Possible causes Remedy
Brake fluid ♦Brake fluid level too low ♦Check brake fluid level and top up
brake fluid if necessary.
Brake distributor ♦System error or system failure of the ♦Read out PSM fault memory (see PSM
PSM control module diagnosis)
Oil pressure too low ♦Oil pressure too low (low oil level). ♦Check oil level. Drain oil and check
whether the specified oil quantity has ♦Mechanical fault of the sensor for the
been filled. oil pressure indicator, oil pump faulty or
malfunctions in the oil circuit ♦Check sensor for oil pressure indicator
Engine temperature too ♦Coolant level too low ♦Check coolant level
high ♦Malfunction in the coolant circuit ♦Read out DME fault memory (see DME
diagnosis)
Engine diagnosis ♦System error or system failure of the ♦Read out DME fault memory (see DME
DME control module diagnosis)
Valve travel control ♦System error or system failure of the ♦Read out DME fault memory (see DME
DME control module diagnosis)
PSM failure ♦Temporary system failure due to com- ♦Read out PSM fault memory (see PSM
munication with the diagnosis tester diagnosis)
♦System error or system failure of the
PSM control module
ABS failure ♦System error or system failure of the ♦Read out PSM fault memory (see PSM
PSM control module (ABS components) diagnosis)
9025 Control module function 90-5 page 1
Printed in Germany – 11, 2001 Sgf_xk20
This is a source reference. Confirm exact model applicability in the original material.