996 Turbo diagnostic manual — Turbo applicability only / PAGE 413

Instrument cluster K20 911 Turbo (996)90 · Tester display Possible causes Remedy

Add to repair workspace
Open repair workspace
Open full manual Original source
Original manual page 413
Read extracted page text

OCR can contain errors. Check the original page image for exact wording, warnings and specifications.

Instrument cluster K20 911 Turbo (996)90 Tester display Possible causes Remedy Brake pad wear ♦Brake pad wear ♦Check brake pads Oil level ♦Oil level too low ♦Read out fault memory of instrument cluster Coolant level ♦Coolant level too low ♦Check coolant level and refill if neces- sary ♦Faults in the wire from expansion tank to instrument cluster or from ground ♦Check wire from ground point 8 to point 8 to expansion tank expansion tank and from expansion tank to instrument cluster and sensor for coolant level. Failure engine-compart- ♦Failure engine-compartment fan ♦Read out DME fault memory (see DME ment fan diagnosis) Coding The following coding options are available under the menu item "Coding": Menu item Function ♦Country coding Selection for following country codings: USA, RoW, UK, Canada, Saudi Arabia and Japan ♦Connect PST 2, switch on ignition and start the automatic control mod- ule search. ♦Select vehicle type 911 (996) and control module instrument cluster ♦Select menu item Coding ♦Select menu item "Country coding" ♦Select the respective country and code with F8 key. ♦Cruise control This menu item enables the instrument cluster to be coded after replacing the instrument cluster or after retrofitting a cruise-control actuator. ♦Connect PST 2, switch on ignition and start the automatic control mod- ule search. ♦Select vehicle type 911 (996) and control module instrument cluster ♦Select menu item Coding ♦Select menu item "Cruise-control actuator" ♦Select the respective menu item with / without cruise-control actuator and code with F8 key 90-5 page 2 9025 Control module function Sgf_xk20 Printed in Germany – 11, 2001

This is a source reference. Confirm exact model applicability in the original material.