996 Turbo diagnostic manual — Turbo applicability only / PAGE 1004

96-12Fault code 6 · Door lock barrel "open/closed", short circuit to

Add to repair workspace
Open repair workspace
Open full manual Original source
Original manual page 1004
Read extracted page text

OCR can contain errors. Check the original page image for exact wording, warnings and specifications.

911 Turbo (996) Alarm system I 48 96 96-12Fault code 6 Door lock barrel "open/closed", short circuit to ground Diagnostic conditions • Door lock barrel actuated in the direction "open" Possible cause of fault ♦Short circuit to ground/open circuit in the wiring between the alarm system control module and both door locks ♦Door lock faulty Affected terminals Plug A, terminals 15 and 35 Diagnosis/troubleshooting Work instruction Display OK If not OK 1 Check wire between ♦Pull plug A off the control mod- ∞ Ω Repair wiring har- alarm system control ule ⇒ Step 2 ness module and door lock → End ♦Pull plug off both door locks (driver/passenger) for ♦Measure the resistance between short circuit to ground plug A pin 15 and ground ♦Measure the resistance between plug A pin 35 and ground 2 Check wire between ♦Switch on ignition 0 V Repair wiring har- alarm system control ⇒ Step 3 ness ♦Measure voltage between plug A module and door lock → End on control module pin 15 and (driver/passenger) for ground short circuit to B+ ♦Measure voltage between plug A on control module pin 35 and ground 9601 Fault code 6 96-12 page 1 Printed in Germany – 4, 2001 6xxxXI48

This is a source reference. Confirm exact model applicability in the original material.