996 Turbo diagnostic manual — Turbo applicability only / PAGE 1006
96-13Fault code 7 · Central locking button closed, short circuit to B+
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
911 Turbo (996) Alarm system I 48 96
96-13Fault code 7
Central locking button closed, short circuit to B+
Diagnostic conditions
• Central locking button actuated
Possible cause of fault
♦Short circuit to voltage in the wiring between the alarm system
control module and the central locking switch
Affected terminals
Plug A, terminal 29
Diagnosis/troubleshooting
Work instruction Display OK If not OK
1 Check central locking ♦Switch off ignition 0 V Repair wiring har-
switch ⇒ Step 2 ness ♦Pull plug A off the control mod-
→ End ule
♦Pull plug off central locking
switch
♦Switch on ignition
♦Measure voltage between plug A
on alarm system control module
pin 29 and ground
2 Check central locking ♦Measure resistance between approx. 180 Ω at 20 Replace resistor or
switch pins 1 and 2 of plug for central °C repair wiring har-
locking switch ⇒ Step 3 ness
→ End
3 Check operating points of ♦Measure resistance between Central locking ⇒ Step 5
central locking switch pins 3 and A1 on central locking switch not actuated → End
switch in "open" direction
∞ Ω ♦Measure resistance between
Central locking pins 4 and 2 on central locking
switch actuated in switch
"open" direction
< 5 Ω
⇒ Step 4
9601 Fault code 7 96-13 page 1
Printed in Germany – 4, 2001 7xxxxi48
This is a source reference. Confirm exact model applicability in the original material.