996 Turbo diagnostic manual — Turbo applicability only / PAGE 1027

96-26Fault code 20 · Status lead, signal converter, short circuit to ground

Add to repair workspace
Open repair workspace
Open full manual Original source
Original manual page 1027
Read extracted page text

OCR can contain errors. Check the original page image for exact wording, warnings and specifications.

911 Turbo (996) Alarm system I 48 96 96-26Fault code 20 Status lead, signal converter, short circuit to ground Diagnostic conditions • Terminal 86S switched on Possible cause of fault ♦Short circuit to ground in the wire between the alarm system control module and the signal converter Affected terminals Plug A, terminals 3 and 4 Diagnosis/troubleshooting Work instruction Display OK If not OK 1 Check wiring from signal ♦Switch off ignition ∞ Ω Repair wiring har- converter to control mod- ⇒ Step 2 ness→ End ♦Pull plug A off the control mod- ule for short circuit to ule ground ♦Pull plug off the signal converter ♦Switch on ignition ♦Measure resistance between plug A on control module pin 4 and ground ♦Measure resistance between plug A on control module pin 3 and ground 2 Check wiring from signal ♦Switch off ignition < 5 Ω Repair wiring har- converter to the control ⇒ Step 3 ness ♦Measure resistance between module for open circuit → End plug A on control module pin 4 and plug on signal converter pin 6 ♦Measure resistance between plug A on control module pin 3 and plug on signal converter pin 8 3 ♦Replace signal converter → End 9601 Fault code 20 96-26 page 1 Printed in Germany – 4, 2001 20xxxi48