996 Turbo diagnostic manual — Turbo applicability only / PAGE 1027
96-26Fault code 20 · Status lead, signal converter, short circuit to ground
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
911 Turbo (996) Alarm system I 48 96
96-26Fault code 20
Status lead, signal converter, short circuit to ground
Diagnostic conditions
• Terminal 86S switched on
Possible cause of fault
♦Short circuit to ground in the wire between the alarm system
control module and the signal converter
Affected terminals
Plug A, terminals 3 and 4
Diagnosis/troubleshooting
Work instruction Display OK If not OK
1 Check wiring from signal ♦Switch off ignition ∞ Ω Repair wiring har-
converter to control mod- ⇒ Step 2 ness→ End ♦Pull plug A off the control mod-
ule for short circuit to ule
ground
♦Pull plug off the signal converter
♦Switch on ignition
♦Measure resistance between
plug A on control module pin 4
and ground
♦Measure resistance between
plug A on control module pin 3
and ground
2 Check wiring from signal ♦Switch off ignition < 5 Ω Repair wiring har-
converter to the control ⇒ Step 3 ness ♦Measure resistance between
module for open circuit → End plug A on control module pin 4
and plug on signal converter pin
6
♦Measure resistance between
plug A on control module pin 3
and plug on signal converter pin
8
3 ♦Replace signal converter → End
9601 Fault code 20 96-26 page 1
Printed in Germany – 4, 2001 20xxxi48
This is a source reference. Confirm exact model applicability in the original material.