996 Turbo diagnostic manual — Turbo applicability only / PAGE 1028
96-27Fault code 21 · W lead (DME - immobilizer), open circuit
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
911 Turbo (996) Alarm system I 48 96
96-27Fault code 21
W lead (DME - immobilizer), open circuit
Diagnostic conditions
• Ignition on
Possible cause of fault
♦Short circuit to ground/open circuit in the communication lead
between the alarm system control module and the DME control
module
Affected terminals
Plug A, terminal 23
Diagnosis/troubleshooting
Work instruction Display OK If not OK
1 Check wire from the ♦Switch off ignition ∞ Ω Repair wiring har-
alarm system control ⇒ Step 2 ness ♦Pull plug A off the alarm system
module to the DME con- → End control module
trol module for short to
♦Pull plug A off the DME control ground.
module
♦Measure resistance between
plug A on alarm system control
module pin 23 and ground
2 Check wire from the ♦Measure resistance between < 5 Ω Repair wiring har-
alarm system control plug A on alarm system control ⇒ Step 3 ness
module to the DME con- module pin 23 and plug A on → End
trol module for open cir- DME control module pin 3
cuit
3 ♦Replace DME control module as a test → End
9601 Fault code 21 96-27 page 1
Printed in Germany – 4, 2001 21xxxi48
This is a source reference. Confirm exact model applicability in the original material.