996 Turbo diagnostic manual — Turbo applicability only / PAGE 1067
96-54Fault code 49 · Diagnostic conditions
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
911 Turbo (996) Alarm system I 48 96
96-54Fault code 49
K lead
Diagnostic conditions
• Ignition on
Possible cause of fault
♦K lead connected to ground for at least 2 seconds after ignition
is switched on
Affected terminals
Plug A, terminal 2
Diagnosis/troubleshooting
Work instruction Display OK If not OK
1 Check the wire from data ♦Pull plug A off the alarm system ∞ Ω Repair wiring har-
link connector to alarm control module ⇒ Step 2 ness
system control module → End ♦Measure resistance between
for short circuit to ground plug A on alarm system control
module pin 2 and ground
2 Check the wire from data ♦Switch on ignition 0 V Repair wiring har-
link connector to alarm ⇒ Step 3 ness ♦Measure voltage between plug A
system control module → End on control module pin 2 and
for short circuit to B+ ground
3 Check the wire from the ♦Switch off ignition < 5 Ω Repair wiring har-
data link connector to the ⇒ Step 4 ness ♦Measure resistance between
alarm system control → End plug A on control module pin 2
module for open circuit and pin 7 on the data link con-
nector
4 ♦Replace control module → End
9601 Fault code 49 96-54 page 1
Printed in Germany – 4, 2001 49xxxi48