996 Turbo diagnostic manual — Turbo applicability only / PAGE 1074
96-60Fault code 58 · No current in tank servomotor despite relay actuation
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
911 Turbo (996) Alarm system I 48 96
96-60Fault code 58
No current in tank servomotor despite relay actuation
Diagnostic conditions
• Central locking system actuation in the direction "safe" or
"locked"
Possible cause of fault
♦Short circuit to ground/open circuit in the wiring between the
switching element for the filler flap and the alarm system control
module
♦Open circuit in wire between ground point 7 and alarm system
control module
♦Switching element for filler flap faulty
♦Control module faulty
Affected terminals
Plug B, terminals 1, 5 and 10
Diagnosis/troubleshooting
Work instruction Display OK If not OK
1 Check wire between ♦Switch off ignition < 5 Ω Repair wiring har-
ground point 7 and alarm ⇒ Step 2 ness ♦Pull plug B off the alarm system
system control module → End control module
for open circuit
♦Measure the resistance between
plug B pin 1 and ground
2 Check the wiring from the ♦Pull plug off switching element ∞ Ω Repair wiring har-
switching element for the for filler flap ⇒ Step 3 ness
filler flap to the alarm sys- → End ♦Measure resistance between
tem control module for plug B on alarm system control
short circuit to ground module pin 5 and ground
♦Measure resistance between
plug B on alarm system control
module pin 10 and ground
9601 Fault code 58 96-60 page 1
Printed in Germany – 4, 2001 58xxxi48
This is a source reference. Confirm exact model applicability in the original material.