996 Turbo diagnostic manual — Turbo applicability only / PAGE 1075

Alarm system I 48 911 Turbo (996)96 · Work instruction Display O

Add to repair workspace
Open repair workspace
Open full manual Original source
Original manual page 1075
Read extracted page text

OCR can contain errors. Check the original page image for exact wording, warnings and specifications.

Alarm system I 48 911 Turbo (996)96 Work instruction Display OK If not OK 2 Check the wiring from the ♦Measure resistance between < 5 Ω Repair wiring har- switching element for the plug B on alarm system control ⇒ Step 3 ness filler flap to the alarm sys- module pin 5 and pin 2 on plug → End tem control module for of switching element for filler open circuit flap ♦Measure resistance between plug B on alarm system control module pin 10 and pin 1 on plug of switching element for filler flap 3 Check output signal of the ♦Select "Filler flap" in menu item A short voltage ⇒ Step 5 alarm system control "Drive links" pulse can be meas- module ured with the digital ♦Perform a drive-link test and multimeter simultaneously measure the volt- ⇒ Step 4 age on the plug of the switching element for filler flap, pins 1 and 2 4 ♦Replace switching element for filler flap → End 5 ♦Replace control module → End 96-60 page 2 9601 Fault code 58 58xxxi48 Printed in Germany – 4, 2001

This is a source reference. Confirm exact model applicability in the original material.