DME 7.8 DME 7.80 · The decimal value displayed multiplied by 0.3921568 gives the load

Add to repair workspace
Open repair workspace
Open full manual Original source
Original manual page 78
Read extracted page text

OCR can contain errors. Check the original page image for exact wording, warnings and specifications.

DME 7.8 DME 7.80 The decimal value displayed multiplied by 0.3921568 gives the load as a percentage. $05 Engine coolant temperature Output of the engine coolant temperature. Display between -40 °C and 215 °C. In the case of decimal output, conversion factor = 1 Offset = -40 °C Decimal value displayed multiplied by 1 minus 40 °C gives the cool- ant temperature. $06 HO2S integrator, bank 1 Output of the control value FR of the oxygen sensor closed-loop con- trol, bank 1. Display: Lean to -100 % Rich to 99.22 % In the case of decimal output, conversion factor = 0.78125 Offset = -100 % Decimal value displayed multiplied by 0.78125 minus 100% gives the HO2S integrator. $07 HO2S adaptation, bank 1 Output of the adaptation value FRA of the oxygen sensor closed- loop control, bank 1. Display: Lean to -100 % Rich to 99.22 % In the case of decimal output, conversion factor = 0.78125 Offset = -100 % Decimal value displayed multiplied by 0.78125 minus 100% gives the HO2S adaptation value. $08 HO2S integrator, bank 2 Output of the control value FR of the oxygen sensor closed-loop con- trol, bank 2. 0-3 page 14 Data output with a scan tool dsc_dm78 Printed in Germany – 8, 2002