fullymatted.
Back to search
Porsche DME 7.8 — OBD II Diagnosis Manual / PAGE 81

DME 7.8 DME 7.8 0 · $83 Dynamic value of the oxygen sensor

Add to repair workspace
Open repair workspace
Open full manual Original source
Original manual page 81
Read extracted page text

OCR can contain errors. Check the original page image for exact wording, warnings and specifications.

DME 7.8 DME 7.8 0 $83 Dynamic value of the oxygen sensor Output of the dynamic value. Display between 0 and 5.0. In the case of decimal output, conversion factor = 0.0195 Decimal value displayed multiplied by 0.0195 gives the dynamic value. $84 Oxygen sensing displacement Oxygen sensing displacement (current share) due to pilot control. Display between -0.05 and 0.05. In the case of decimal output, conversion factor = 0.00039 Offset = -128 Decimal value displayed multiplied by 0.00039 minus 128 gives the oxygen sensing displacement. For the oxygen sensors after the TWC (bank 1/2, sensor 2), the following TIDs are supported: $01 Rich-lean threshold voltage Programmed fixed value: e.g. 0.575 V. In the case of decimal output, conversion factor = 0.005 Decimal value displayed multiplied by 0.005 gives the threshold voltage. $02 Lean-rich threshold voltage Programmed fixed value: e.g. 0.575 V. In the case of decimal output, conversion factor = 0.005 Decimal value displayed multiplied by 0.005 gives the threshold voltage. $07 Minimum voltage of oxygen sensor during the test Minimum: e.g. 0.000 V Maximum: e.g. 0.480 V Test value: e.g. 0.280 V In the case of decimal output, conversion factor = 0.005 Data output with a scan tool 0-3 page 17 Printed in Germany – 8, 2002 dsc_dm78

This is a source reference. Confirm exact model applicability in the original material.