DME 7.8 DME 7.80 · Decimal value displayed multiplied by 0.005 gives the threshold

Add to repair workspace
Open repair workspace
Open full manual Original source
Original manual page 82
Read extracted page text

OCR can contain errors. Check the original page image for exact wording, warnings and specifications.

DME 7.8 DME 7.80 Decimal value displayed multiplied by 0.005 gives the threshold voltage. $08 Maximum voltage of oxygen sensor during the test Minimum: e.g. 0.480 V Maximum: e.g. 1.245 V Test value: e.g. 0.685 V In the case of decimal output, conversion factor = 0.005 Decimal value displayed multiplied by 0.005 gives the threshold voltage. Mode 6 The test results of components or systems which are not continu- ously monitored are output in mode 6. At the same time, limit values are provided. The test results are referred to as TIDs (Test Identifi- cation). The components or systems are distinguished by CIDs (Component Identification). The following components or systems are supported: TID $01 Catalytic converter monitoring The catalytic converters (bank 1/bank 2) are monitored individually and for the sum of the emissions. There are two threshold values for individual monitoring: ♦AHKATMN for the OK detection and ♦AHKATMX for the defect detection. For the sum of the emissions, there is the AHKATSB threshold value. A number (ahkat) which is between 0 and 1 is used as a measure for the aging of the catalytic converters. 0 - good 0-3 page 18 Data output with a scan tool dsc_dm78 Printed in Germany – 8, 2002