DME 7.8 DME 7.8 0 · 0-17P0118

Add to repair workspace
Open repair workspace
Open full manual Original source
Original manual page 242
Read extracted page text

OCR can contain errors. Check the original page image for exact wording, warnings and specifications.

DME 7.8 DME 7.8 0 0-17P0118 123 Engine temperature - above limit Diagnosis conditions • A fault is recorded after a debounce time of 0.4 seconds if an engine temperature of more than 140°C is measured. Possible fault cause ♦Wiring ♦Temperature sensor faulty ♦DME control module faulty Affected terminals Terminal III/22 and III/17 Resistance values 0 °C 5.0 - 7.0 kΩ 20 °C 2.0 - 3.0 kΩ 60 °C 0.4 - 0.8 kΩ Diagnosis/troubleshooting Work instruction Display OK If not OK 1 Check temperature sen- ♦Remove plug connection in Approx. 2 - 3 kΩ Replace tempera- sor engine compartment ⇒ Step 1 ture sensor → End ♦Measure resistance between temperature sensor Pin 1 and Pin 4 2 Check output voltage of ♦Connect special tool 9637. Do Approx. 5 V ⇒ Step 3 DME control module not connect connector III of vehi- → End cle wiring harness. ♦Measure voltage between Pin III/ 22 and III/17 ♦Ignition on 2462 P0118 0-17 page 1 Printed in Germany, 2000 p0118