DME 7.8 DME 7.8 0 · 0-65P0441

Add to repair workspace
Open repair workspace
Open full manual Original source
Original manual page 537
Read extracted page text

OCR can contain errors. Check the original page image for exact wording, warnings and specifications.

DME 7.8 DME 7.8 0 0-65P0441 93 Fuel Tank Ventilation System - Above Limit Diagnosis conditions • Engine idling • Vehicle speed = 0 km/h • Oxygen sensing system active • No secondary air diagnosis • No other faults in memory Possible fault cause ♦EVAP canister purge valve incorrectly installed ♦EVAP canister purge valve faulty ♦Blocked purge air line ♦EVAP canister purge valve leaking ♦Leaking line between EVAP canister and air intake system Affected terminals - Diagnosis/troubleshooting Note! Fuel tank ventilation diagnosis is initiated with the Porsche System Tester 2 in the "Short test" menu. This reduces the time elapsed after engine start-up to 30 seconds. Work instruction Display OK If not OK 1 Check installation position Flow through the EVAP canister of EVAP canister purge purge valve is possible in one direc- valve tion only. The flow direction is indi- cated by an arrow on the EVAP canister purge valve. The arrow must point towards the intake mani- fold. 2 Check triggering of EVAP ♦Connect Porsche System Tester The EVAP canister canister purge valve. 2 purge valve must switch audibly. ♦In the "Drive links" menu, select EVAP canister purge valve. 2023 P0441 0-65 page 1 Printed in Germany – 1, 2000 p0441

This is a source reference. Confirm exact model applicability in the original material.