Porsche DME 7.8 — OBD II Diagnosis Manual / PAGE 554
DME 7.8 DME 7.8 0 · 0-71P0448
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
DME 7.8 DME 7.8 0
0-71P0448
96 EVAP canister shutoff valve (output stage) - over
limit
Diagnosis conditions
• Engine running
• Battery voltage greater than 7 V
• Fuel tank ventilation active
Possible fault cause
♦Wiring harness
♦DME control module faulty
Note!
Fuel tank ventilation can be activated with the Porsche System
Tester 2 in the ’Short test’ menu.
Affected terminals
Terminal IV/30
Diagnosis/troubleshooting
Work instruction Display OK If not OK
1 Check triggering wire for ♦Remove front right-hand wheel 0 V Repair wiring har-
shutoff valve for short to housing liner ⇒ Step 2 ness
B+ → End ♦Remove connector of shutoff
valve
♦Remove DME control module
connector
♦Measure voltage between shut-
off valve plug Pin 1 and ground
♦Switch on the ignition
2 Replace DME control module ⇒ Step 3
3 Perform adaptation ♦Switch on the ignition → End
♦Wait one minute
♦Do not press the accelerator
♦Switch off the ignition for at
least 10 seconds
♦Read out the fault memory
2093 P0448 0-71 page 1
Printed in Germany, 2000 p0448