Porsche DME 7.8 — OBD II Diagnosis Manual / PAGE 555
DME 7.8 DME 7.80 · 96 EVAP canister shutoff valve (output stage) - under
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
DME 7.8 DME 7.80
96 EVAP canister shutoff valve (output stage) - under
limit
Diagnosis conditions
• Engine running
• Battery voltage greater than 7 V
• Fuel tank ventilation active
Possible fault cause
♦Wiring harness
♦DME control module faulty
Note!
Fuel tank ventilation can be activated with the Porsche System
Tester 2 in the ’Short test’ menu.
Affected terminals
Terminal IV/30
Diagnosis/troubleshooting
Work instruction Display OK If not OK
1 Check triggering wire for ♦Remove front right-hand wheel ∞ Ω Repair wiring har-
shutoff valve for short to housing liner ⇒ Step 2 ness
ground → End ♦Remove connector of shutoff
valve
♦Remove DME control module
connector
♦Measure resistance between
shutoff valve plug Pin 1 and
ground
♦Switch on the ignition
2 Replace DME control module ⇒ Step 3
3 Perform adaptation ♦Switch on the ignition → End
♦Wait one minute
♦Do not press the accelerator
♦Switch off the ignition for at
least 10 seconds
♦Read out the fault memory
0-71 page 2 2093 P0448
p0448 Printed in Germany, 2000
This is a source reference. Confirm exact model applicability in the original material.