Porsche DME 7.8 — OBD II Diagnosis Manual / PAGE 571
DME 7.8 DME 7.8 0 · ♦Do not produce a vacuum of more than 100 mbar, as o
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
DME 7.8 DME 7.8 0
Figure:
Note!
♦Do not produce a vacuum of more than 100 mbar, as otherwise
the vacuum will cause the shutoff valve to open.
♦If no vacuum can be built up, replace the shutoff valve.
♦Coat the sealing ring of the new shutoff valve with tyre fitting
lubricant prior to installation.
♦The shutoff valve can only be installed in one position: with the
electrical connection facing upwards.
Work instruction Display OK If not OK
2 Check tank system for ♦Check the tank system for leaks
leaks using an HC tester. To do so,
hold the connecting hose of the
HC tester in the spot to be
tested. In the case of a leak, the
display of the HC tester
increases to above 1000 ppm.
Values below 50 ppm indicate
no leaks.
♦To test the ventilation lines,
guide the connecting hose
slowly along them.
♦Check the following locations
1. Tank cap
2. Line connections to EVAP can-
ister
3. EVAP canister
4. Line connections to fuel tank
sender unit
5. Pressure sensor
6. Opening of fuel filler neck into
tank
7. Line connection of EVAP canis-
ter purge valve
8. Ventilation lines
2023 P0456 0-75.1 page 3
Printed in Germany – 6, 2002 p0456
This is a source reference. Confirm exact model applicability in the original material.