Porsche DME 7.8 — OBD II Diagnosis Manual / PAGE 601

DME 7.8 DME 7.8 0 · 0-81.1P0513

Add to repair workspace
Open repair workspace
Open full manual Original source
Original manual page 601
Read extracted page text

OCR can contain errors. Check the original page image for exact wording, warnings and specifications.

DME 7.8 DME 7.8 0 0-81.1P0513 Immobilizer – Signal Implausible Diagnosis conditions • Start condition • Motronic reset Possible fault cause ♦Open circuit in wiring between DME control module and alarm system ♦Short circuit to ground or short circuit to B+ ♦Alarm system control module faulty Affected terminals - Diagnosis/Troubleshooting Work instruction Display OK If not OK 1 Check signal wire for con- ♦Remove connector I of alarm 0 - 5 Ω Step 2. tinuity system control module Step 3. ♦Connect special tool 9637 to wiring harness (DME control module plug). ♦Measure resistance between special tool 9637 Pin I/3 and alarm system control module plug Pin I/23 2 Remove connector X 2/3 ♦Measure resistance between 0 - 5 Ω Repair wiring har- plug connection X 2/3 bushing Step 3. ness 6 and special tool 9637 Pin I/3 → End. ♦Measure resistance between plug connection X 2/3 Pin 6 and alarm system control module plug I Pin 23 9068 P0513 0-81.1 page 1 Printed in Germany – 6, 2002 p0513