fullymatted.
Back to search
Porsche DME 7.8 — OBD II Diagnosis Manual / PAGE 602

DME 7.8 DME 7.80 · Work instruction Display OK

Add to repair workspace
Open repair workspace
Open full manual Original source
Original manual page 602
Read extracted page text

OCR can contain errors. Check the original page image for exact wording, warnings and specifications.

DME 7.8 DME 7.80 Work instruction Display OK If not OK 3 Check signal wire for ♦Remove connector I of alarm ∞ Ω Repair wiring har- short circuit to ground system control module Step 4. ness → End. ♦Connect special tool 9637 to wiring harness (DME control module plug). ♦Measure resistance between special tool 9637 Pin I/3 and ground 4 Check signal wire for ♦Remove connector I of alarm 0 V Repair wiring har- short circuit to B+ system control module Step 4. ness → End. ♦Connect special tool 9637 to wiring harness (DME control module plug). ♦Measure voltage between spe- cial tool 9637 Pin I/3 and ground 5 Replace alarm system control module. → End. → End. Immobilizer - Open Circuit Diagnosis conditions • Start condition • Motronic reset Possible fault cause ♦Open circuit in wiring between DME control module and alarm system ♦Short circuit to ground or short circuit to B+ ♦Alarm system control module faulty Affected terminals - 0-81.1 page 2 9068 P0513 p0513 Printed in Germany – 6, 2002

This is a source reference. Confirm exact model applicability in the original material.