Porsche DME 7.8 — OBD II Diagnosis Manual / PAGE 710

DME 7.8 DME 7.80 · Do not exchange oxygen sensors ahead of catalytic converter and

Add to repair workspace
Open repair workspace
Open full manual Original source
Original manual page 710
Read extracted page text

OCR can contain errors. Check the original page image for exact wording, warnings and specifications.

DME 7.8 DME 7.80 Note! Do not exchange oxygen sensors ahead of catalytic converter and after catalytic converter. Oxygen sensors ahead of and after catalytic converter 1 - Oxygen sensor ahead of catalytic converter 2 - Oxygen sensor after catalytic converter 1 2 5 Oxygen Sensor Heating Ahead of TWC, Bank 2 – Above Limit Diagnosis conditions • Battery voltage between 9.5 V and 16 V • Time elapsed after engine start-up greater than 10 seconds Possible fault cause ♦Short circuit to B+ Affected terminals II/13 Diagnosis/Troubleshooting 0-109 page 6 2469 P1119 p1119 Printed in Germany – 2, 2000