fullymatted.
Back to search
Porsche DME 7.8 — OBD II Diagnosis Manual / PAGE 709

DME 7.8 DME 7.8 0 · Oxygen sensors ahead of and after catalytic converte

Add to repair workspace
Open repair workspace
Open full manual Original source
Original manual page 709
Read extracted page text

OCR can contain errors. Check the original page image for exact wording, warnings and specifications.

DME 7.8 DME 7.8 0 Oxygen sensors ahead of and after catalytic converter 1 - Oxygen sensor ahead of catalytic converter 2 - Oxygen sensor after catalytic converter 1 2 5 Oxygen Sensor Heating Ahead of TWC, Bank 2 – Below Limit Diagnosis conditions • Battery voltage between 9.5 V and 16 V • Time elapsed after engine start-up greater than 10 seconds Possible fault cause ♦Short circuit to ground Affected terminals II/13 Diagnosis/Troubleshooting Note! Do not use contact spray on the connectors to oxygen sensor. Work instruction Display OK If not OK 1 Check oxygen sensor ♦Remove oxygen sensor connec- 3.0 to 3.5 Ω at 20 Replace oxygen heating tor Bank 2 ahead of catalytic °C sensor converter ♦Check resistance between pin 3 and 4 towards the oxygen sen- sor 2 ♦Check resistance between pin 4 ∞ Ω and the oxygen sensor housing 3 Check wiring ♦Check resistance between pin 4 ∞ Ω Repair wiring har- and vehicle ground towards ness DME control module 2469 P1119 0-109 page 5 Printed in Germany – 2, 2000 p1119

This is a source reference. Confirm exact model applicability in the original material.