7 captured repliesDiscussion pagination complete · Source accounts, not a confirmed diagnosis
THIS DISCUSSION / SOURCE-DERIVED OVERVIEW
Discussion summary
YOUR RESEARCHPuzzled, baffled even...
Leading reported evidence
Install 0
Performed · outcome unconfirmed
No successful repair reported for this finding.
0
Reported fixes
0
Unsuccessful attempts
1
Discussions
Read evidence and context
Explicit resolution reports before identified causes, performed actions and suggestions. Within each level, matching component labels precede direct query mentions and inherited thread context; successful versus unsuccessful discussion counts, owner confirmations and independent discussion support determine order. This is not a probability of success.
Discussions that performed work without a confirmed outcome
1
0 original-poster resolution reports. Counts can overlap; they are not unique people or a success rate.
0 discussions have direct query context; 0 report a fix in that context. Other evidence may inherit the discussion’s subject.
Performed · outcome unconfirmed · Original poster
Today I installed a 0.27 ohm 2 watt resistor to replace the ~0.030 nichrome(?) metal link and now the flasher relay seems to work fine, proper blink rate, with the original incandescents or LED lamps.
Leading evidence: 'Install 0' (no explicit attributable resolution; this is a reported action or suggestion). Across 1 matching discussions, the most frequently mentioned possible cause is 'right way' (1 discussions; 0 report identifying it and 1 suggest it). The most frequently discussed action is 'Install 0' (1 discussions). For that action, 0 discussions report a resolution and 0 report an unsuccessful attempt. No action has an explicit, attributable resolution report under the current rules. These are forum reports and suggestions, not a confirmed diagnosis.
Source reports, not a diagnosis or a success probability. Counts refer to discussions and can overlap.
Explicit resolution reports before identified causes, performed actions and suggestions. Within each level, matching component labels precede direct query mentions and inherited thread context; successful versus unsuccessful discussion counts, owner confirmations and independent discussion support determine order. This is not a probability of success.
Discussions that suspect a cause
1
0 original-poster resolution reports. Counts can overlap; they are not unique people or a success rate.
0 discussions have direct query context; 0 report a fix in that context. Other evidence may inherit the discussion’s subject.
Explicit resolution reports before identified causes, performed actions and suggestions. Within each level, matching component labels precede direct query mentions and inherited thread context; successful versus unsuccessful discussion counts, owner confirmations and independent discussion support determine order. This is not a probability of success.
Discussions that contain suggestions
1
0 original-poster resolution reports. Counts can overlap; they are not unique people or a success rate.
0 discussions have direct query context; 0 report a fix in that context. Other evidence may inherit the discussion’s subject.
Suggestion
Will, instead of a different relay, just run a dummy load resistor.
These are separate views of the same evidence. Frequency alone does not establish a fix, and these counts must not be added together.
Install 0
No successful repair reported for this finding.
0
Reported fixes
0
Unsuccessful attempts
1
Discussions
Read evidence and context
Discussions that performed work without a confirmed outcome
1
0 original-poster resolution reports. Counts can overlap; they are not unique people or a success rate.
0 discussions have direct query context; 0 report a fix in that context. Other evidence may inherit the discussion’s subject.
Performed · outcome unconfirmed · Original poster
Today I installed a 0.27 ohm 2 watt resistor to replace the ~0.030 nichrome(?) metal link and now the flasher relay seems to work fine, proper blink rate, with the original incandescents or LED lamps.
Counts describe captured discussions, not unique people or a diagnosis. Author identities are not reliably stored. Exact duplicate evidence is counted once across matching discussions; one discussion counts at most once per action/state. Multiple repairs reported together remain a combination. Suggestions and failed attempts do not establish a fix. Matches cover whole discussions and can include related faults, model variants and incomplete threads.
7 eligible posts · 0 unverified posts · 1 discussions match the subject in their title or opening post.
Rennlist: 1 discussions
0 evidence records excluded for query context · 0 excluded by outcome qualification · 0 adjusted by outcome qualification.
0 acknowledgements have no verified action link; they do not establish a repair result.
Generation: 20261027T201111Z · outcome-qualification-6. Deterministic extraction; no AI model inference. How we use sources
I've been in the process of converting as many light bulbs, stop, street/parking, marker, etc, to LED type lamps.
The turn signal lamp flasher system has me stumped.
The factory flasher relay (branded VW ) is solid state yet it will not flash at the "standard" rate with a low bulb current draw. Also the pin-out, 3 "lugs", has exactly the same physical layout as the solid state one in my 2001 E350 MH.
But every "third-party" flasher relay that I try will blow the 15 amp turn signal fuse.
Anyone with experience or ideas for a solution?
Will, instead of a different relay, just run a dummy load resistor.
www.jamstrait.com
has one,
http://www.jamstrait.com/loadeq.html
, and you can find more with google probably.
Ths solid state relays still flash fast or not at all with low current bulbs, it is a bulb check.
Disassembled the factory flasher relay today and I'm pretty sure I found the small resistance that is used to detect that the total current draw is equal to or greater than the ~2 amps that it takes to power two 1156 incandescent turn signal bulbs. Actually just a simple metal "U" link through which the lamp current must flow, each end connected to a separate pin of an intergrated circuit. Drop across the link is 0.061 volts with 2 amps of current flow. Now I need to measure the current flow for powering two 1156 LED lamps and replace the link with a resistor size that drops ~61 millivolts.
Tomorrow.
It's now tomorrow.
Type 1156 turn signal lamp draws 1.86 amps at ~13 volts, vs 0.180 amps for my chosen LED lamp, Velocity Leds. Looks like a 0.3 ohm 2 watt resister will work and fit into the assembly easily.
Today I installed a 0.27 ohm 2 watt resistor to replace the ~0.030 nichrome(?) metal link and now the flasher relay seems to work fine, proper blink rate, with the original incandescents or LED lamps. Flasher relay cover was easily removed and the nichrome link/resistance is all too obvious.