fullymatted.
Back to search
PistonHeads

Boxster 987 air con fan issue - Page 1 - Boxster/Cayman - PistonHeads UK

Add to repair workspace
Open repair workspace
Original source
12 captured repliesPartial discussion capture · Source accounts, not a confirmed diagnosis
THIS DISCUSSION / SOURCE-DERIVED OVERVIEW

Discussion summary

YOUR RESEARCHBoxster 987 air con fan issue - Page 1 - Boxster/Cayman - PistonHeads UK

Reported or suspected cause

motor

Suggestion or failed attempt

No successful repair reported for this finding.

0
Identified cause
1
Suspected cause
0
Reported fixes
Read evidence and context

Explicit resolution reports before identified causes, performed actions and suggestions. Within each level, matching component labels precede direct query mentions and inherited thread context; successful versus unsuccessful discussion counts, owner confirmations and independent discussion support determine order. This is not a probability of success.

Discussions that suspect a cause
1

0 original-poster resolution reports. Counts can overlap; they are not unique people or a success rate.

0 discussions have direct query context; 0 report a fix in that context. Other evidence may inherit the discussion’s subject.

Suspected cause

Hi as Rochster says, both fans will run with the A/C on, if one fails the the otherside will run at max speed,fault is more than likely the motor, which is superceeded to gen 2 versions, or front control unit has been known to burn out.

Boxster 987 air con fan issue - Page 1 - Boxster/Cayman - PistonHeads UK
Frequently discussed work

Check noise and air draft at both frontal intakes

No successful repair reported for this finding.

0
Reported fixes
0
Unsuccessful attempts
1
Discussions
Read evidence and context
Discussions that contain suggestions
1

0 original-poster resolution reports. Counts can overlap; they are not unique people or a success rate.

0 discussions have direct query context; 0 report a fix in that context. Other evidence may inherit the discussion’s subject.

Suggestion

Check for noise and air draft at both frontal intakes.

Boxster 987 air con fan issue - Page 1 - Boxster/Cayman - PistonHeads UK
Read full discussion summary

Leading evidence: 'motor' (no explicit attributable resolution; this is a reported action or suggestion). Across 1 matching discussions, the most frequently mentioned possible cause is 'motor' (1 discussions; 0 report identifying it and 1 suggest it). The most frequently discussed action is 'Check noise and air draft at both frontal intakes' (1 discussions). For that action, 0 discussions report a resolution and 0 report an unsuccessful attempt. No action has an explicit, attributable resolution report under the current rules. These are forum reports and suggestions, not a confirmed diagnosis.

Source reports, not a diagnosis or a success probability. Counts refer to discussions and can overlap.

Read captured replies

1 matching discussions · 12 captured posts examined · 1 partial discussions

Compare 4 other evidence results

Check noise and air draft at both frontal intakes

Suggestion or failed attempt

No successful repair reported for this finding.

0
Reported fixes
0
Unsuccessful attempts
1
Discussions
Read evidence and context

Explicit resolution reports before identified causes, performed actions and suggestions. Within each level, matching component labels precede direct query mentions and inherited thread context; successful versus unsuccessful discussion counts, owner confirmations and independent discussion support determine order. This is not a probability of success.

Discussions that contain suggestions
1

0 original-poster resolution reports. Counts can overlap; they are not unique people or a success rate.

0 discussions have direct query context; 0 report a fix in that context. Other evidence may inherit the discussion’s subject.

Suggestion

Check for noise and air draft at both frontal intakes.

Boxster 987 air con fan issue - Page 1 - Boxster/Cayman - PistonHeads UK

Run best hooked up

Suggestion or failed attempt

No successful repair reported for this finding.

0
Reported fixes
0
Unsuccessful attempts
1
Discussions
Read evidence and context

Explicit resolution reports before identified causes, performed actions and suggestions. Within each level, matching component labels precede direct query mentions and inherited thread context; successful versus unsuccessful discussion counts, owner confirmations and independent discussion support determine order. This is not a probability of success.

Discussions that contain suggestions
1

0 original-poster resolution reports. Counts can overlap; they are not unique people or a success rate.

0 discussions have direct query context; 0 report a fix in that context. Other evidence may inherit the discussion’s subject.

Suggestion

If one fan still running best hooked up to tester as can be a few different faults.

Boxster 987 air con fan issue - Page 1 - Boxster/Cayman - PistonHeads UK

Run consistently

Suggestion or failed attempt

No successful repair reported for this finding.

0
Reported fixes
0
Unsuccessful attempts
1
Discussions
Read evidence and context

Explicit resolution reports before identified causes, performed actions and suggestions. Within each level, matching component labels precede direct query mentions and inherited thread context; successful versus unsuccessful discussion counts, owner confirmations and independent discussion support determine order. This is not a probability of success.

Discussions that contain suggestions
1

0 original-poster resolution reports. Counts can overlap; they are not unique people or a success rate.

0 discussions have direct query context; 0 report a fix in that context. Other evidence may inherit the discussion’s subject.

Suggestion

The fans both should run consistently when AC switched on.

Boxster 987 air con fan issue - Page 1 - Boxster/Cayman - PistonHeads UK

Run on engine demand

Suggestion or failed attempt

No successful repair reported for this finding.

0
Reported fixes
0
Unsuccessful attempts
1
Discussions
Read evidence and context

Explicit resolution reports before identified causes, performed actions and suggestions. Within each level, matching component labels precede direct query mentions and inherited thread context; successful versus unsuccessful discussion counts, owner confirmations and independent discussion support determine order. This is not a probability of success.

Discussions that contain suggestions
1

0 original-poster resolution reports. Counts can overlap; they are not unique people or a success rate.

0 discussions have direct query context; 0 report a fix in that context. Other evidence may inherit the discussion’s subject.

Suggestion

They only run on engine demand for cooling ...or when AC switched on .

Boxster 987 air con fan issue - Page 1 - Boxster/Cayman - PistonHeads UK
Frequently discussed actions (8)

These are separate views of the same evidence. Frequency alone does not establish a fix, and these counts must not be added together.

Check noise and air draft at both frontal intakes

No successful repair reported for this finding.

0
Reported fixes
0
Unsuccessful attempts
1
Discussions
Read evidence and context
Discussions that contain suggestions
1

0 original-poster resolution reports. Counts can overlap; they are not unique people or a success rate.

0 discussions have direct query context; 0 report a fix in that context. Other evidence may inherit the discussion’s subject.

Suggestion

Check for noise and air draft at both frontal intakes.

Boxster 987 air con fan issue - Page 1 - Boxster/Cayman - PistonHeads UK

Run best hooked up

No successful repair reported for this finding.

0
Reported fixes
0
Unsuccessful attempts
1
Discussions
Read evidence and context
Discussions that contain suggestions
1

0 original-poster resolution reports. Counts can overlap; they are not unique people or a success rate.

0 discussions have direct query context; 0 report a fix in that context. Other evidence may inherit the discussion’s subject.

Suggestion

If one fan still running best hooked up to tester as can be a few different faults.

Boxster 987 air con fan issue - Page 1 - Boxster/Cayman - PistonHeads UK

Run consistently

No successful repair reported for this finding.

0
Reported fixes
0
Unsuccessful attempts
1
Discussions
Read evidence and context
Discussions that contain suggestions
1

0 original-poster resolution reports. Counts can overlap; they are not unique people or a success rate.

0 discussions have direct query context; 0 report a fix in that context. Other evidence may inherit the discussion’s subject.

Suggestion

The fans both should run consistently when AC switched on.

Boxster 987 air con fan issue - Page 1 - Boxster/Cayman - PistonHeads UK

Run on engine demand

No successful repair reported for this finding.

0
Reported fixes
0
Unsuccessful attempts
1
Discussions
Read evidence and context
Discussions that contain suggestions
1

0 original-poster resolution reports. Counts can overlap; they are not unique people or a success rate.

0 discussions have direct query context; 0 report a fix in that context. Other evidence may inherit the discussion’s subject.

Suggestion

They only run on engine demand for cooling ...or when AC switched on .

Boxster 987 air con fan issue - Page 1 - Boxster/Cayman - PistonHeads UK

Run with the a/c

No successful repair reported for this finding.

0
Reported fixes
0
Unsuccessful attempts
1
Discussions
Read evidence and context
Discussions that contain suggestions
1

0 original-poster resolution reports. Counts can overlap; they are not unique people or a success rate.

0 discussions have direct query context; 0 report a fix in that context. Other evidence may inherit the discussion’s subject.

Suggestion

Hi as Rochster says, both fans will run with the A/C on, if one fails the the otherside will run at max speed,fault is more than likely the motor, which is superceeded to gen 2 versions, or front control unit has been known to burn out.

Boxster 987 air con fan issue - Page 1 - Boxster/Cayman - PistonHeads UK

Set dependant

No successful repair reported for this finding.

0
Reported fixes
0
Unsuccessful attempts
1
Discussions
Read evidence and context
Discussions that contain suggestions
1

0 original-poster resolution reports. Counts can overlap; they are not unique people or a success rate.

0 discussions have direct query context; 0 report a fix in that context. Other evidence may inherit the discussion’s subject.

Suggestion

Both fans have a low and high speed setting dependant on the load on the systems.

Boxster 987 air con fan issue - Page 1 - Boxster/Cayman - PistonHeads UK

Test should identify the fault...it may be

No successful repair reported for this finding.

0
Reported fixes
0
Unsuccessful attempts
1
Discussions
Read evidence and context
Discussions that contain suggestions
1

0 original-poster resolution reports. Counts can overlap; they are not unique people or a success rate.

0 discussions have direct query context; 0 report a fix in that context. Other evidence may inherit the discussion’s subject.

Suggestion

A test should identify the fault...it may be that the ballast resistor has failed and the fan been wired direct to power supply to get it to work.

Boxster 987 air con fan issue - Page 1 - Boxster/Cayman - PistonHeads UK

Use same fans

No successful repair reported for this finding.

0
Reported fixes
0
Unsuccessful attempts
1
Discussions
Read evidence and context
Discussions that contain suggestions
1

0 original-poster resolution reports. Counts can overlap; they are not unique people or a success rate.

0 discussions have direct query context; 0 report a fix in that context. Other evidence may inherit the discussion’s subject.

Suggestion

They use the same fans for both.

Boxster 987 air con fan issue - Page 1 - Boxster/Cayman - PistonHeads UK
Reported and suspected causes (1)

These are separate views of the same evidence. Frequency alone does not establish a fix, and these counts must not be added together.

motor

No successful repair reported for this finding.

0
Identified cause
1
Suspected cause
0
Reported fixes
Read evidence and context
Discussions that suspect a cause
1

0 original-poster resolution reports. Counts can overlap; they are not unique people or a success rate.

0 discussions have direct query context; 0 report a fix in that context. Other evidence may inherit the discussion’s subject.

Suspected cause

Hi as Rochster says, both fans will run with the A/C on, if one fails the the otherside will run at max speed,fault is more than likely the motor, which is superceeded to gen 2 versions, or front control unit has been known to burn out.

Boxster 987 air con fan issue - Page 1 - Boxster/Cayman - PistonHeads UK
Coverage and how to read this overview

Counts describe captured discussions, not unique people or a diagnosis. Author identities are not reliably stored. Exact duplicate evidence is counted once across matching discussions; one discussion counts at most once per action/state. Multiple repairs reported together remain a combination. Suggestions and failed attempts do not establish a fix. Matches cover whole discussions and can include related faults, model variants and incomplete threads.

12 eligible posts · 0 unverified posts · 1 discussions match the subject in their title or opening post.

  • PistonHeads: 1 discussions

0 evidence records excluded for query context · 0 excluded by outcome qualification · 0 adjusted by outcome qualification.

1 acknowledgements have no verified action link; they do not establish a repair result.

Outcome without a verified action link

Around 90c ,and switch off when engine back to normal temp.

No unique explicit quoted action; no causal link assigned

Generation: 20261026T152433Z · outcome-qualification-6. Deterministic extraction; no AI model inference. How we use sources

POST 1 / ORIGINAL POSTEROriginal post

Hi Guys Is anyone able to help with this problem? 2010 MY Drivers side fan runs full pelt but nothing from passenger side(these are fans at front of car) Engine on or just on ignition. Drivers side fan on all time driving and stays on for 20 mins or so afterwards. Fan not blocked,turns freely by hand. air con works normally. Hope you can help. regards

POST 2Original post

cavyhazel said: Hi Guys Is anyone able to help with this problem? 2010 MY Drivers side fan runs full pelt but nothing from passenger side(these are fans at front of car) Engine on or just on ignition. Drivers side fan on all time driving and stays on for 20 mins or so afterwards. Fan not blocked,turns freely by hand. air con works normally. Hope you can help. regards Reads like the passenger side radiator fan is dead. It happens. My Turbo's passinger fan motor shaft snapped believe it or not. Then not too long ago the driver's side fan motor still ran but hardly blew any air and the tech found its current draw was quite high so I had him replace it. And back some years ago I found my Boxster's passenger fan not running. There is enough margin the engine coolant temperature will be ok and the A/C will work just fine. When my Turbo fan was not working I noticed this not because of any A/C issues even though the ambient temperature was in the 90's but the difference in fan noise had me out of the car and then I found the passenger side fan not working. Best get the car to a shop and get the fan sorted. If the other fan goes out the engine can overheat.

POST 3Original post

During normal driving the cooling fans should switch on when engine temp high enough to need cooling . Around 90c ,and switch off when engine back to normal temp. This can be monitored by differences on engine temp gauge. The fans both should run consistently when AC switched on. Both fans have a low and high speed setting dependant on the load on the systems. The fan not running may be u/s ballast resistor ( very common fault) . Constant running fan ....could be many things ,maybe best have it hooked up to tester. Regards. I .

POST 4Original post

Hi as Rochster says, both fans will run with the A/C on, if one fails the the otherside will run at max speed,fault is more than likely the motor, which is superceeded to gen 2 versions, or front control unit has been known to burn out. Chris

POST 5 / ORIGINAL POSTEROriginal post

Thanks for your replies ,but are we talking about the same thing. You talk about engine temp ,but these radiators are for the air comn and situated at front bumper. The 987 varies from the 986 in that it is connected via the edu i believe.I could do with a wiring diagram.

POST 6 / ORIGINAL POSTEROriginal post

Thanks for your replies ,but are we talking about the same thing. You talk about engine temp ,but these radiators are for the air comn and situated at front bumper. The 987 varies from the 986 in that it is connected via the edu i believe.I could do with a wiring diagram.

POST 7Original post

The ballast resistor is a common fault on 996s. If you can find out whether they still use them on 987s I would recommend checking that. The engine radiators and a/c condensers are both at the front on both sides, one in front of the other. They use the same fans for both. Edited by AndrewsCayman on Friday 21st August 09:27

POST 8Original post

Hi Cavy,yes we are talking about same issue, the radiator fan pulls air through condensor, to cool it down when ever the A/C is on. If you find somebody with a Porsche diagnostic tester, the faulty fan will be stored in system, Chris

POST 9 / ORIGINAL POSTEROriginal post

hi cd1957 Thanks for this. now with the a/c off the drivers fan still runs,does that point to anything,or is it just cooling the engine also .

POST 10Original post

Easy check...when engine cold at start up ...and AC off ....no fans should be running. They only run on engine demand for cooling ...or when AC switched on . Check for noise and air draft at both frontal intakes. If one fan still running best hooked up to tester as can be a few different faults.

POST 11 / ORIGINAL POSTEROriginal post

Hi Polome When i switch ignition on or when i then start engine ,drivers side fan comes on full. Have booked it in with Indy to hook up to tester.Let you all know the outcome for future reference.

POST 12Original post

A test should identify the fault...it may be that the ballast resistor has failed and the fan been wired direct to power supply to get it to work. Ie a bodge. Good luck. Ian