Check fuses related

Performed · outcome unconfirmed

No successful repair reported for this finding.

0
Reported fixes
0
Unsuccessful attempts
1
Discussions
Read evidence and context

Explicit resolution reports before identified causes, performed actions and suggestions. Within each level, matching component labels precede direct query mentions and inherited thread context; successful versus unsuccessful discussion counts, owner confirmations and independent discussion support determine order. This is not a probability of success.

Discussions that performed work without a confirmed outcome
1

0 original-poster resolution reports. Counts can overlap; they are not unique people or a success rate.

0 discussions have direct query context; 0 report a fix in that context. Other evidence may inherit the discussion’s subject.

Performed · outcome unconfirmed · Original poster

I checked all the fuses related to the engine and they all ok.

Help with electrical system
Read full discussion summary

Leading evidence: 'Check fuses related' (no explicit attributable resolution; this is a reported action or suggestion). Across 1 matching discussions, The most frequently discussed action is 'Check fuses related' (1 discussions). For that action, 0 discussions report a resolution and 0 report an unsuccessful attempt. No action has an explicit, attributable resolution report under the current rules. These are forum reports and suggestions, not a confirmed diagnosis.

Source reports, not a diagnosis or a success probability. Counts refer to discussions and can overlap.

Read captured replies

1 matching discussions · 16 captured posts examined · 0 partial discussions

Compare 4 other evidence results

Replace blown radio fuse

Performed · outcome unconfirmed

No successful repair reported for this finding.

0
Reported fixes
0
Unsuccessful attempts
1
Discussions
Read evidence and context

Explicit resolution reports before identified causes, performed actions and suggestions. Within each level, matching component labels precede direct query mentions and inherited thread context; successful versus unsuccessful discussion counts, owner confirmations and independent discussion support determine order. This is not a probability of success.

Discussions that performed work without a confirmed outcome
1

0 original-poster resolution reports. Counts can overlap; they are not unique people or a success rate.

0 discussions have direct query context; 0 report a fix in that context. Other evidence may inherit the discussion’s subject.

Performed · outcome unconfirmed · Original poster

Blown radio fuse was replaced.

Help with electrical system

Check relay anyway

Suggestion or failed attempt

No successful repair reported for this finding.

0
Reported fixes
0
Unsuccessful attempts
1
Discussions
Read evidence and context

Explicit resolution reports before identified causes, performed actions and suggestions. Within each level, matching component labels precede direct query mentions and inherited thread context; successful versus unsuccessful discussion counts, owner confirmations and independent discussion support determine order. This is not a probability of success.

Discussions that contain suggestions
1

0 original-poster resolution reports. Counts can overlap; they are not unique people or a success rate.

0 discussions have direct query context; 0 report a fix in that context. Other evidence may inherit the discussion’s subject.

Suggestion · Original poster

How do I check a relay anyway?

Help with electrical system

Check relays mentioned above yet

Suggestion or failed attempt

No successful repair reported for this finding.

0
Reported fixes
0
Unsuccessful attempts
1
Discussions
Read evidence and context

Explicit resolution reports before identified causes, performed actions and suggestions. Within each level, matching component labels precede direct query mentions and inherited thread context; successful versus unsuccessful discussion counts, owner confirmations and independent discussion support determine order. This is not a probability of success.

Discussions that contain suggestions
1

0 original-poster resolution reports. Counts can overlap; they are not unique people or a success rate.

0 discussions have direct query context; 0 report a fix in that context. Other evidence may inherit the discussion’s subject.

Suggestion

Have you checked the relays mentioned above yet?

Help with electrical system

Check voltage at the smaller terminal 50

Suggestion or failed attempt

No successful repair reported for this finding.

0
Reported fixes
0
Unsuccessful attempts
1
Discussions
Read evidence and context

Explicit resolution reports before identified causes, performed actions and suggestions. Within each level, matching component labels precede direct query mentions and inherited thread context; successful versus unsuccessful discussion counts, owner confirmations and independent discussion support determine order. This is not a probability of success.

Discussions that contain suggestions
1

0 original-poster resolution reports. Counts can overlap; they are not unique people or a success rate.

0 discussions have direct query context; 0 report a fix in that context. Other evidence may inherit the discussion’s subject.

Suggestion

You might check the voltage at the smaller terminal 50 on the solenoid when an assistant attempts to start the engine.

Help with electrical system
Frequently discussed actions (8)

These are separate views of the same evidence. Frequency alone does not establish a fix, and these counts must not be added together.

Check fuses related

No successful repair reported for this finding.

0
Reported fixes
0
Unsuccessful attempts
1
Discussions
Read evidence and context
Discussions that performed work without a confirmed outcome
1

0 original-poster resolution reports. Counts can overlap; they are not unique people or a success rate.

0 discussions have direct query context; 0 report a fix in that context. Other evidence may inherit the discussion’s subject.

Performed · outcome unconfirmed · Original poster

I checked all the fuses related to the engine and they all ok.

Help with electrical system

Check relay anyway

No successful repair reported for this finding.

0
Reported fixes
0
Unsuccessful attempts
1
Discussions
Read evidence and context
Discussions that contain suggestions
1

0 original-poster resolution reports. Counts can overlap; they are not unique people or a success rate.

0 discussions have direct query context; 0 report a fix in that context. Other evidence may inherit the discussion’s subject.

Suggestion · Original poster

How do I check a relay anyway?

Help with electrical system

Check relays mentioned above yet

No successful repair reported for this finding.

0
Reported fixes
0
Unsuccessful attempts
1
Discussions
Read evidence and context
Discussions that contain suggestions
1

0 original-poster resolution reports. Counts can overlap; they are not unique people or a success rate.

0 discussions have direct query context; 0 report a fix in that context. Other evidence may inherit the discussion’s subject.

Suggestion

Have you checked the relays mentioned above yet?

Help with electrical system

Check voltage at the smaller terminal 50

No successful repair reported for this finding.

0
Reported fixes
0
Unsuccessful attempts
1
Discussions
Read evidence and context
Discussions that contain suggestions
1

0 original-poster resolution reports. Counts can overlap; they are not unique people or a success rate.

0 discussions have direct query context; 0 report a fix in that context. Other evidence may inherit the discussion’s subject.

Suggestion

You might check the voltage at the smaller terminal 50 on the solenoid when an assistant attempts to start the engine.

Help with electrical system

Replace blown radio fuse

No successful repair reported for this finding.

0
Reported fixes
0
Unsuccessful attempts
1
Discussions
Read evidence and context
Discussions that performed work without a confirmed outcome
1

0 original-poster resolution reports. Counts can overlap; they are not unique people or a success rate.

0 discussions have direct query context; 0 report a fix in that context. Other evidence may inherit the discussion’s subject.

Performed · outcome unconfirmed · Original poster

Blown radio fuse was replaced.

Help with electrical system

Replace relay or a master fuse

No successful repair reported for this finding.

0
Reported fixes
0
Unsuccessful attempts
1
Discussions
Read evidence and context
Discussions that contain suggestions
1

0 original-poster resolution reports. Counts can overlap; they are not unique people or a success rate.

0 discussions have direct query context; 0 report a fix in that context. Other evidence may inherit the discussion’s subject.

Suggestion · Original poster

if it's something as easy as replacing a relay or a master fuse....

Help with electrical system

Use flashlight you can see the starter

No successful repair reported for this finding.

0
Reported fixes
0
Unsuccessful attempts
1
Discussions
Read evidence and context
Discussions that contain suggestions
1

0 original-poster resolution reports. Counts can overlap; they are not unique people or a success rate.

0 discussions have direct query context; 0 report a fix in that context. Other evidence may inherit the discussion’s subject.

Suggestion

If you open the engine lid and use a flashlight you can see the starter with electrical connections on the solenoid.

Help with electrical system

Use insulated jumpers

No successful repair reported for this finding.

0
Reported fixes
0
Unsuccessful attempts
1
Discussions
Read evidence and context
Discussions that contain suggestions
1

0 original-poster resolution reports. Counts can overlap; they are not unique people or a success rate.

0 discussions have direct query context; 0 report a fix in that context. Other evidence may inherit the discussion’s subject.

Suggestion

Use insulated jumpers with clips and keep your hands out of the engine bay and any wires away from rotating parts.

Help with electrical system
Coverage and how to read this overview

Counts describe captured discussions, not unique people or a diagnosis. Author identities are not reliably stored. Exact duplicate evidence is counted once across matching discussions; one discussion counts at most once per action/state. Multiple repairs reported together remain a combination. Suggestions and failed attempts do not establish a fix. Matches cover whole discussions and can include related faults, model variants and incomplete threads.

16 eligible posts · 0 unverified posts · 1 discussions match the subject in their title or opening post.

  • Rennlist: 1 discussions

0 evidence records excluded for query context · 0 excluded by outcome qualification · 0 adjusted by outcome qualification.

1 acknowledgements have no verified action link; they do not establish a repair result.

Outcome without a verified action link

We want to hear how you solved this problem.

No unique explicit quoted action; no causal link assigned

Generation: 20261027T031046Z · outcome-qualification-6. Deterministic extraction; no AI model inference. How we use sources

POST 1 / ORIGINAL POSTEROriginal post

While jump starting the car (it sat idle for 2 month) my dad reversed polarity on the cables while attaching it to the rear point ( in the engine bay). Now the starter does not work, but everything else seems to be working. I checked all the fuses related to the engine and they all ok. Blown radio fuse was replaced. There is a set of relays above fuse box, and I wonder if one of them is blown. Any help would be greatly appreciated.

POST 2Original post

Relay for ignition? 2nd in from left on top row of relay carrier under carpet in back seat.

POST 3 / ORIGINAL POSTEROriginal post

Where exactly is that? Before I start ripping the car apart..

POST 4Original post

Behind the rear seats under the carpet. The computer and a relay box is there. The computer is on the left (looking out the back window) and the relay box is on the right. I am only guessing that this could bethe cause.. Does your ignition switch work? All lights, dash, radio, etc? The only other thing I can think of is that you fried the solenoid on the starter. Do you get at least a "ckick" when you turn the ignition? Or nothing? The relays I would look at behind the seat would be (at least on the 99 C2) top row second from left (this is the ignition relay) and the botoom row extreme left (this is the starter cutoff relay).

POST 5 / ORIGINAL POSTEROriginal post

My car is a cab and I see some relays behind the carpet, but they are behind rollover popup bars and very hard to get to. Most of the electrical stuff works. Ignition key turns everything on, except electrical top, which just clicks and does nothing. I will have to go visti a dealer and talk to a technician. I just hate to fltabed the car. if it's something as easy as replacing a relay or a master fuse....

POST 6Original post

The starter circuit for the 996 Porsche is pretty standard. Voltage from battery to the ignition switch to the permissive relay (permission from depressed clutch or (or Tiptronic Park/Neutral)) and to the starter solenoid. If you open the engine lid and use a flashlight you can see the starter with electrical connections on the solenoid. It is just below and left of the throttle body. When you turn the ignition switch, the permissive relay should power the smaller terminal (50) which should engage the solenoid and apply power to the starter via terminal (30). There is a fusible Element in the power distribution box, but if this were blown you shouldn't get power to the other items you say are working OK. You might check the voltage at the smaller terminal 50 on the solenoid when an assistant attempts to start the engine. (Be careful here) If you don't get any voltage then you might trace backwards to the permissive relay behind the rear left seatback. If you get 12 volts at terminal 50 but the starter does not turn, then remove the plastic cap on the supply cable to the starter to see if you have voltage there. It should have 12 volts always. It may be possible to free the starter by banging on it in case you welded up something or reverse rotation disturbed the brushes. The starter comes out toward the rear by removing the throttle body and the plastic intake distributer if you are inclined to do it yourself. It may be possible to jump the starter by putting 12 volts on terminal 50 in case you turning the ignition to start does not give any voltage there. Again be careful. Use insulated jumpers with clips and keep your hands out of the engine bay and any wires away from rotating parts. Once the battery is dead you lose the usual things: Radio Code (depends on model) DME adaptation - there is a procedure for readapting Stored Control Module faults Tiptronic adaptation Power Window limit switches - there is a procedure for this too Trip computer, Clock, Date - easy to set PCM data Fuel Level accuracy (depends on model)

POST 7 / ORIGINAL POSTEROriginal post

Thanks guys, Do you have schematic of relays behind left rear seat? Thanks

POST 8Original post

According to my schematics, the start lock relay is in position 7 on the 12 socket relay panel. It is a standard 4 plug relay. Although I never checked this particular relay on my own car, typically the cube shows the relay schematic as a relief in the molded plastic. 87 From Ignition switch 86 coil 12v 85 coil ground 30 To starter Solenoid If you remove the relay and jump from 87 to 30, you bypass any start permissives or locks.

POST 9Original post

Also: There is a seprate 40 amp maxi fuse associated with the relay panel, described as position 13. It must be outside the 12 cube relay panel. Not sure how it is wired without more digging. If it powers the whole relay panel the rear spoiler (relays 3 & 9) would also be failed. Also, there is a box near the battery called the current distributer. It contains a number of fusible links visible if the cover is removed. There is an 80 amp link for the ignition lock. Does turning the key have any effect?

POST 10Original post

The fuse in the relay box is for the auxilary air pump and has nothing to do with the starter relay. The number 7 relay is the second row left as I stated above. He still hasn't answered whether or dot he gets ANY noise from the starter when he turns the ignition on. Is it a tip or manual?

POST 11 / ORIGINAL POSTEROriginal post

There is no noise from starter at all. The lights do not dim on the dashboard. Another thing that is not working is convertible top. There is click sound in the back, but top does not operate. I can turn head lights and they dim when I turn ignition to start engine, so some relays must be working and it indicates that ignition switch is also operable. It's a TIP transmission. Thanks

POST 12Original post

Have you checked the relays mentioned above yet?

POST 13 / ORIGINAL POSTEROriginal post

I pulled the carpet behind rear seats and seen the box with relay. in my cab they are behind the pop up bars housing, so they are extremely hard to access. How do I check a relay anyway? Do I go buy a new one from the dealer and try replacing it? Because I don't think they will have any visible marks from burning out. There is also set of dozen or so relays above fuse box. Can any of them be the ones?

POST 15Original post

By reversing the polarity with the jumpers, the obvious item you might have fried is the battery itself. It sounds like the high power items are the ones that are not working. The headlights lights dimming when ignition is turned to start may indicate the battery cannot keep the voltage up. You can measure voltage cell to cell (about 2 volts each cell x 6 cells = 12 volts). Put the voltmeter leads right into the liquid (acid). All cells should be the same 2V. The link shown by 1999Porsche911 shows your exact relay, and a previous post already mentioned how to jump this out of the circuit. A cheap voltmeter at radio shack is less than the cost to flatbed your car. We want to hear how you solved this problem.

POST 16 / ORIGINAL POSTEROriginal post

The verdict is in... Fried ECU. Waiting to get a replacemant and looking for IPO to pay for the price tag of ECU -> $2.2K plus labor