Leading reported evidence

Repair .(yes i have my epa 609 certification)

Suggestion or failed attempt

No successful repair reported for this finding.

0
Reported fixes
0
Unsuccessful attempts
1
Discussions
Read evidence and context

Explicit resolution reports before identified causes, performed actions and suggestions. Within each level, matching component labels precede direct query mentions and inherited thread context; successful versus unsuccessful discussion counts, owner confirmations and independent discussion support determine order. This is not a probability of success.

Discussions that contain suggestions
1

0 original-poster resolution reports. Counts can overlap; they are not unique people or a success rate.

0 discussions have direct query context; 0 report a fix in that context. Other evidence may inherit the discussion’s subject.

Suggestion

Well, I have all the required equipment(AC recover machine, recovery tanks, multiple gauges) but I do LOTS of AC repair.(Yes I have my EPA 609 certification)

Needed 40psi at low side for coold AC
Read full discussion summary

Leading evidence: 'Repair .(yes i have my epa 609 certification)' (no explicit attributable resolution; this is a reported action or suggestion). Across 1 matching discussions, The most frequently discussed action is 'Repair .(yes i have my epa 609 certification)' (1 discussions). For that action, 0 discussions report a resolution and 0 report an unsuccessful attempt. No action has an explicit, attributable resolution report under the current rules. These are forum reports and suggestions, not a confirmed diagnosis.

Source reports, not a diagnosis or a success probability. Counts refer to discussions and can overlap.

Read captured replies

1 matching discussions · 6 captured posts examined · 0 partial discussions

Frequently discussed actions (1)

These are separate views of the same evidence. Frequency alone does not establish a fix, and these counts must not be added together.

Repair .(yes i have my epa 609 certification)

No successful repair reported for this finding.

0
Reported fixes
0
Unsuccessful attempts
1
Discussions
Read evidence and context
Discussions that contain suggestions
1

0 original-poster resolution reports. Counts can overlap; they are not unique people or a success rate.

0 discussions have direct query context; 0 report a fix in that context. Other evidence may inherit the discussion’s subject.

Suggestion

Well, I have all the required equipment(AC recover machine, recovery tanks, multiple gauges) but I do LOTS of AC repair.(Yes I have my EPA 609 certification)

Needed 40psi at low side for coold AC
Coverage and how to read this overview

Counts describe captured discussions, not unique people or a diagnosis. Author identities are not reliably stored. Exact duplicate evidence is counted once across matching discussions; one discussion counts at most once per action/state. Multiple repairs reported together remain a combination. Suggestions and failed attempts do not establish a fix. Matches cover whole discussions and can include related faults, model variants and incomplete threads.

6 eligible posts · 0 unverified posts · 1 discussions match the subject in their title or opening post.

  • Rennlist: 1 discussions

0 evidence records excluded for query context · 0 excluded by outcome qualification · 0 adjusted by outcome qualification.

0 acknowledgements have no verified action link; they do not establish a repair result.

Generation: 20261026T200546Z · outcome-qualification-6. Deterministic extraction; no AI model inference. How we use sources

POST 1 / ORIGINAL POSTEROriginal post

Hi, My AC has slowly become worse and worse (over a few years). It stopped blowing any cold at all. I added some R134 using one of those fillers and now it blows cold. However, I started at 30psi but had to fill it to 40-45psi in order to get some cold. This was with an outside temp of 85 F. Could this just be the pressure gauge being off or does 996s require higher pressure than other cars? Seems like 30psi should be enough. Or is something else wrong? thanks

POST 2Original post

It is ambient temperature dependent. At 85degF you should target 45-55psi Low-side and 225-250psi High-side You really need some gauges that measure high and low to do it correctly. A lot of consumer freon low-side only gauge/freon stuff says to add until 35psi, but that's only good for 70-75deg.

POST 3 / ORIGINAL POSTEROriginal post

Quotes source post: 16705423

oh thanks! Is there a table or something that I should refer to? I just followed the instructions on the Bottle. Worth investing in a proper gauge setup? Or should I just be happy with it working now. I am fine with having a slow slow slow leak, cheaper to fill it up than to to have someone fix it....

POST 4Original post

Quotes source post: 16705434

Yes, I have a chart on my wall. Let me check and see where I found it, or I'll post a photo of it. Well, I have all the required equipment(AC recover machine, recovery tanks, multiple gauges) but I do LOTS of AC repair.(Yes I have my EPA 609 certification) I've already done 6 system repairs so far this year even with COVID. But cheap gauges are available from Harbor Freight (really good gauges BTW) or Amazon. You'll need a can tap for the gauges, but they're cheap on Amazon too.

This is a source reference. Confirm exact model applicability in the original material.