replacing undermount aircon pipes

Add to repair workspace
Open repair workspace
Original source
8 captured repliesDiscussion pagination complete · Source accounts, not a confirmed diagnosis
THIS DISCUSSION / SOURCE-DERIVED OVERVIEW

Discussion summary

YOUR RESEARCHreplacing undermount aircon pipes

Reported or suspected cause

those clips

Reported cause

No successful repair reported for this finding.

1
Identified cause
0
Suspected cause
0
Reported fixes
Read evidence and context

Explicit resolution reports before identified causes, performed actions and suggestions. Within each level, matching component labels precede direct query mentions and inherited thread context; successful versus unsuccessful discussion counts, owner confirmations and independent discussion support determine order. This is not a probability of success.

Discussions that report identifying a cause
1

0 original-poster resolution reports. Counts can overlap; they are not unique people or a success rate.

0 discussions have direct query context; 0 report a fix in that context. Other evidence may inherit the discussion’s subject.

Reported cause · Original poster

The problem is those clips.

replacing undermount aircon pipes
Frequently discussed work

Replace air con pipes

No successful repair reported for this finding.

0
Reported fixes
0
Unsuccessful attempts
1
Discussions
Read evidence and context
Discussions that performed work without a confirmed outcome
1

0 original-poster resolution reports. Counts can overlap; they are not unique people or a success rate.

0 discussions have direct query context; 0 report a fix in that context. Other evidence may inherit the discussion’s subject.

Performed · outcome unconfirmed · Original poster

So I have changed both air con pipes that run under the sill.

replacing undermount aircon pipes
Read full discussion summary

Leading evidence: 'those clips' (1 discussions report identifying this cause; no attributable repair resolution). Across 1 matching discussions, the most frequently mentioned possible cause is 'those clips' (1 discussions; 1 report identifying it and 0 suggest it). The most frequently discussed action is 'Replace air con pipes' (1 discussions). For that action, 0 discussions report a resolution and 0 report an unsuccessful attempt. No action has an explicit, attributable resolution report under the current rules. These are forum reports and suggestions, not a confirmed diagnosis.

Source reports, not a diagnosis or a success probability. Counts refer to discussions and can overlap.

Read captured replies

1 matching discussions · 8 captured posts examined · 0 partial discussions

Compare 4 other evidence results

Replace air con pipes

Performed · outcome unconfirmed

No successful repair reported for this finding.

0
Reported fixes
0
Unsuccessful attempts
1
Discussions
Read evidence and context

Explicit resolution reports before identified causes, performed actions and suggestions. Within each level, matching component labels precede direct query mentions and inherited thread context; successful versus unsuccessful discussion counts, owner confirmations and independent discussion support determine order. This is not a probability of success.

Discussions that performed work without a confirmed outcome
1

0 original-poster resolution reports. Counts can overlap; they are not unique people or a success rate.

0 discussions have direct query context; 0 report a fix in that context. Other evidence may inherit the discussion’s subject.

Performed · outcome unconfirmed · Original poster

So I have changed both air con pipes that run under the sill.

replacing undermount aircon pipes

Run under the sill

Suggestion or failed attempt

No successful repair reported for this finding.

0
Reported fixes
0
Unsuccessful attempts
1
Discussions
Read evidence and context

Explicit resolution reports before identified causes, performed actions and suggestions. Within each level, matching component labels precede direct query mentions and inherited thread context; successful versus unsuccessful discussion counts, owner confirmations and independent discussion support determine order. This is not a probability of success.

Discussions that contain suggestions
1

0 original-poster resolution reports. Counts can overlap; they are not unique people or a success rate.

0 discussions have direct query context; 0 report a fix in that context. Other evidence may inherit the discussion’s subject.

Suggestion · Original poster

So I have changed both air con pipes that run under the sill.

replacing undermount aircon pipes

Use adhesive

Suggestion or failed attempt

No successful repair reported for this finding.

0
Reported fixes
0
Unsuccessful attempts
1
Discussions
Read evidence and context

Explicit resolution reports before identified causes, performed actions and suggestions. Within each level, matching component labels precede direct query mentions and inherited thread context; successful versus unsuccessful discussion counts, owner confirmations and independent discussion support determine order. This is not a probability of success.

Discussions that contain suggestions
1

0 original-poster resolution reports. Counts can overlap; they are not unique people or a success rate.

0 discussions have direct query context; 0 report a fix in that context. Other evidence may inherit the discussion’s subject.

Suggestion

You could also argue that since these pipes undergo a fairly significant thermal delta (given what they're used for), using an adhesive that completely limits longitudinal movement for a body that regularly increases and decreases in length due to thermal expansion could also fatigue the metal.

replacing undermount aircon pipes

Use some construction adhesive, i personally like locktite pl premium

Suggestion or failed attempt

No successful repair reported for this finding.

0
Reported fixes
0
Unsuccessful attempts
1
Discussions
Read evidence and context

Explicit resolution reports before identified causes, performed actions and suggestions. Within each level, matching component labels precede direct query mentions and inherited thread context; successful versus unsuccessful discussion counts, owner confirmations and independent discussion support determine order. This is not a probability of success.

Discussions that contain suggestions
1

0 original-poster resolution reports. Counts can overlap; they are not unique people or a success rate.

0 discussions have direct query context; 0 report a fix in that context. Other evidence may inherit the discussion’s subject.

Suggestion

That or use some construction adhesive, I personally like Locktite PL Premium that stuff is the bomb.

replacing undermount aircon pipes
Frequently discussed actions (4)

These are separate views of the same evidence. Frequency alone does not establish a fix, and these counts must not be added together.

Replace air con pipes

No successful repair reported for this finding.

0
Reported fixes
0
Unsuccessful attempts
1
Discussions
Read evidence and context
Discussions that performed work without a confirmed outcome
1

0 original-poster resolution reports. Counts can overlap; they are not unique people or a success rate.

0 discussions have direct query context; 0 report a fix in that context. Other evidence may inherit the discussion’s subject.

Performed · outcome unconfirmed · Original poster

So I have changed both air con pipes that run under the sill.

replacing undermount aircon pipes

Run under the sill

No successful repair reported for this finding.

0
Reported fixes
0
Unsuccessful attempts
1
Discussions
Read evidence and context
Discussions that contain suggestions
1

0 original-poster resolution reports. Counts can overlap; they are not unique people or a success rate.

0 discussions have direct query context; 0 report a fix in that context. Other evidence may inherit the discussion’s subject.

Suggestion · Original poster

So I have changed both air con pipes that run under the sill.

replacing undermount aircon pipes

Use adhesive

No successful repair reported for this finding.

0
Reported fixes
0
Unsuccessful attempts
1
Discussions
Read evidence and context
Discussions that contain suggestions
1

0 original-poster resolution reports. Counts can overlap; they are not unique people or a success rate.

0 discussions have direct query context; 0 report a fix in that context. Other evidence may inherit the discussion’s subject.

Suggestion

You could also argue that since these pipes undergo a fairly significant thermal delta (given what they're used for), using an adhesive that completely limits longitudinal movement for a body that regularly increases and decreases in length due to thermal expansion could also fatigue the metal.

replacing undermount aircon pipes

Use some construction adhesive, i personally like locktite pl premium

No successful repair reported for this finding.

0
Reported fixes
0
Unsuccessful attempts
1
Discussions
Read evidence and context
Discussions that contain suggestions
1

0 original-poster resolution reports. Counts can overlap; they are not unique people or a success rate.

0 discussions have direct query context; 0 report a fix in that context. Other evidence may inherit the discussion’s subject.

Suggestion

That or use some construction adhesive, I personally like Locktite PL Premium that stuff is the bomb.

replacing undermount aircon pipes
Reported and suspected causes (1)

These are separate views of the same evidence. Frequency alone does not establish a fix, and these counts must not be added together.

those clips

No successful repair reported for this finding.

1
Identified cause
0
Suspected cause
0
Reported fixes
Read evidence and context
Discussions that report identifying a cause
1

0 original-poster resolution reports. Counts can overlap; they are not unique people or a success rate.

0 discussions have direct query context; 0 report a fix in that context. Other evidence may inherit the discussion’s subject.

Reported cause · Original poster

The problem is those clips.

replacing undermount aircon pipes
Coverage and how to read this overview

Counts describe captured discussions, not unique people or a diagnosis. Author identities are not reliably stored. Exact duplicate evidence is counted once across matching discussions; one discussion counts at most once per action/state. Multiple repairs reported together remain a combination. Suggestions and failed attempts do not establish a fix. Matches cover whole discussions and can include related faults, model variants and incomplete threads.

8 eligible posts · 0 unverified posts · 1 discussions match the subject in their title or opening post.

  • Rennlist: 1 discussions

0 evidence records excluded for query context · 0 excluded by outcome qualification · 0 adjusted by outcome qualification.

0 acknowledgements have no verified action link; they do not establish a repair result.

Generation: 20261026T091943Z · outcome-qualification-6. Deterministic extraction; no AI model inference. How we use sources

POST 1 / ORIGINAL POSTEROriginal post

So I have changed both air con pipes that run under the sill. The problem is those clips. They are held on by a plastic hollow bolt onto a welded thread onto the car floor, Problem is the welded threads rust and become smooth, the new plastic clips have nothing to bite onto. So they rattle about. Has anyone solved this? I was thinking silicone glue between the clip and floor

POST 2Original post

That or use some construction adhesive, I personally like Locktite PL Premium that stuff is the bomb. If you ever need to get it off, you could chip/grind it off....but it doesn't sound like something you would do soon. Just put it on, and let the car sit for 24 hours and you'll be set. http://www.loctiteproducts.com/const...dhesives.shtml There is other stuff on the same page that is clear. Anything like this will work.

POST 4Original post

I'd go with the silicone, since when it cures it will be rubbery and help damp vibration. Anything that sets up very hard is another vibration opportunity...

POST 6Original post

Quotes source post: 11817739

If it's going be rubbery, it will allow the pipes to flex more, which would create more of a low stress, high cycle fatigue. I personally would want the fasteners tight to the body to minimize relative motion between the pipes and the body. Rubbing is not good.....unless you are with a hooker in Reno!

POST 8Original post

Cyclical fatigue can happen regardless of the viscosity of the adhesive. Since we don't know the resonant frequency of the lines in their original state, and we have no idea about the degrees of freedom provided by the original fasteners, postulating that a non-rigid adhesive will result in fatigue failure seems a little...intentionally academic. In my unscientifically-founded opinion, a good-sized gob of silicone is going to work just fine for damping the AC lines. They're already bouncing around unrestrained and haven't failed; securing them in some manner is probably better than leaving them alone. You could also argue that since these pipes undergo a fairly significant thermal delta (given what they're used for), using an adhesive that completely limits longitudinal movement for a body that regularly increases and decreases in length due to thermal expansion could also fatigue the metal. If this was my car: I'd plop down a blob of RTV and check it off as "good enough." I wish I had something as clever as the Reno Hooker analogy to polish this off with - that's good stuff...

This is a source reference. Confirm exact model applicability in the original material.