fullymatted.
Back to search
Rennlist

Self healing AOS?

Add to repair workspace
Open repair workspace
Original source
19 captured repliesDiscussion pagination complete · Source accounts, not a confirmed diagnosis
THIS DISCUSSION / SOURCE-DERIVED OVERVIEW

Discussion summary

YOUR RESEARCHSelf healing AOS?

Reported or suspected cause

aos/regulator, period

Reported cause

No successful repair reported for this finding.

1
Identified cause
0
Suspected cause
0
Reported fixes
Read evidence and context

Explicit resolution reports before identified causes, performed actions and suggestions. Within each level, matching component labels precede direct query mentions and inherited thread context; successful versus unsuccessful discussion counts, owner confirmations and independent discussion support determine order. This is not a probability of success.

Discussions that report identifying a cause
1

0 original-poster resolution reports. Counts can overlap; they are not unique people or a success rate.

0 discussions have direct query context; 0 report a fix in that context. Other evidence may inherit the discussion’s subject.

Reported cause

A high reading of the crankcase vacuum is caused by a failing AOS/regulator, period.

Self healing AOS?
Frequently discussed work

Replace battery and retest

No successful repair reported for this finding.

0
Reported fixes
0
Unsuccessful attempts
1
Discussions
Read evidence and context
Discussions that contain suggestions
1

0 original-poster resolution reports. Counts can overlap; they are not unique people or a success rate.

0 discussions have direct query context; 0 report a fix in that context. Other evidence may inherit the discussion’s subject.

Suggestion · Original poster

Someone suggested I change the battery and retest.

Self healing AOS?
Read full discussion summary

Leading evidence: 'aos/regulator, period' (1 discussions report identifying this cause; no attributable repair resolution). Across 1 matching discussions, the most frequently mentioned possible cause is 'aos/regulator, period' (1 discussions; 1 report identifying it and 0 suggest it). The most frequently discussed action is 'Replace battery and retest' (1 discussions). For that action, 0 discussions report a resolution and 0 report an unsuccessful attempt. No action has an explicit, attributable resolution report under the current rules. These are forum reports and suggestions, not a confirmed diagnosis.

Source reports, not a diagnosis or a success probability. Counts refer to discussions and can overlap.

Read captured replies

1 matching discussions · 19 captured posts examined · 0 partial discussions

Compare 4 other evidence results

leak in the regulator diaphragm, and depending

Reported cause

No successful repair reported for this finding.

1
Identified cause
0
Suspected cause
0
Reported fixes
Read evidence and context

Explicit resolution reports before identified causes, performed actions and suggestions. Within each level, matching component labels precede direct query mentions and inherited thread context; successful versus unsuccessful discussion counts, owner confirmations and independent discussion support determine order. This is not a probability of success.

Discussions that report identifying a cause
1

0 original-poster resolution reports. Counts can overlap; they are not unique people or a success rate.

0 discussions have direct query context; 0 report a fix in that context. Other evidence may inherit the discussion’s subject.

Reported cause

As far as AOS failure causing intermittent readings, the #1 cause is a leak in the regulator diaphragm, and depending on the size of the leak will determine the effect on the Diaphragm Regulator Control.

Self healing AOS?

Replace battery and retest

Suggestion or failed attempt

No successful repair reported for this finding.

0
Reported fixes
0
Unsuccessful attempts
1
Discussions
Read evidence and context

Explicit resolution reports before identified causes, performed actions and suggestions. Within each level, matching component labels precede direct query mentions and inherited thread context; successful versus unsuccessful discussion counts, owner confirmations and independent discussion support determine order. This is not a probability of success.

Discussions that contain suggestions
1

0 original-poster resolution reports. Counts can overlap; they are not unique people or a success rate.

0 discussions have direct query context; 0 report a fix in that context. Other evidence may inherit the discussion’s subject.

Suggestion · Original poster

Someone suggested I change the battery and retest.

Self healing AOS?

Test fashioned way

Suggestion or failed attempt

No successful repair reported for this finding.

0
Reported fixes
0
Unsuccessful attempts
1
Discussions
Read evidence and context

Explicit resolution reports before identified causes, performed actions and suggestions. Within each level, matching component labels precede direct query mentions and inherited thread context; successful versus unsuccessful discussion counts, owner confirmations and independent discussion support determine order. This is not a probability of success.

Discussions that contain suggestions
1

0 original-poster resolution reports. Counts can overlap; they are not unique people or a success rate.

0 discussions have direct query context; 0 report a fix in that context. Other evidence may inherit the discussion’s subject.

Suggestion · Original poster

Maybe I need to test the old fashioned way with a slack tube.

Self healing AOS?

Test under identical conditions

Suggestion or failed attempt

No successful repair reported for this finding.

0
Reported fixes
0
Unsuccessful attempts
1
Discussions
Read evidence and context

Explicit resolution reports before identified causes, performed actions and suggestions. Within each level, matching component labels precede direct query mentions and inherited thread context; successful versus unsuccessful discussion counts, owner confirmations and independent discussion support determine order. This is not a probability of success.

Discussions that contain suggestions
1

0 original-poster resolution reports. Counts can overlap; they are not unique people or a success rate.

0 discussions have direct query context; 0 report a fix in that context. Other evidence may inherit the discussion’s subject.

Suggestion

Did you test under identical conditions?

Self healing AOS?
Frequently discussed actions (4)

These are separate views of the same evidence. Frequency alone does not establish a fix, and these counts must not be added together.

Replace battery and retest

No successful repair reported for this finding.

0
Reported fixes
0
Unsuccessful attempts
1
Discussions
Read evidence and context
Discussions that contain suggestions
1

0 original-poster resolution reports. Counts can overlap; they are not unique people or a success rate.

0 discussions have direct query context; 0 report a fix in that context. Other evidence may inherit the discussion’s subject.

Suggestion · Original poster

Someone suggested I change the battery and retest.

Self healing AOS?

Test fashioned way

No successful repair reported for this finding.

0
Reported fixes
0
Unsuccessful attempts
1
Discussions
Read evidence and context
Discussions that contain suggestions
1

0 original-poster resolution reports. Counts can overlap; they are not unique people or a success rate.

0 discussions have direct query context; 0 report a fix in that context. Other evidence may inherit the discussion’s subject.

Suggestion · Original poster

Maybe I need to test the old fashioned way with a slack tube.

Self healing AOS?

Test under identical conditions

No successful repair reported for this finding.

0
Reported fixes
0
Unsuccessful attempts
1
Discussions
Read evidence and context
Discussions that contain suggestions
1

0 original-poster resolution reports. Counts can overlap; they are not unique people or a success rate.

0 discussions have direct query context; 0 report a fix in that context. Other evidence may inherit the discussion’s subject.

Suggestion

Did you test under identical conditions?

Self healing AOS?

Use rational thought

No successful repair reported for this finding.

0
Reported fixes
0
Unsuccessful attempts
1
Discussions
Read evidence and context
Discussions that contain suggestions
1

0 original-poster resolution reports. Counts can overlap; they are not unique people or a success rate.

0 discussions have direct query context; 0 report a fix in that context. Other evidence may inherit the discussion’s subject.

Suggestion

There you go, using rational thought.

Self healing AOS?
Reported and suspected causes (2)

These are separate views of the same evidence. Frequency alone does not establish a fix, and these counts must not be added together.

aos/regulator, period

No successful repair reported for this finding.

1
Identified cause
0
Suspected cause
0
Reported fixes
Read evidence and context
Discussions that report identifying a cause
1

0 original-poster resolution reports. Counts can overlap; they are not unique people or a success rate.

0 discussions have direct query context; 0 report a fix in that context. Other evidence may inherit the discussion’s subject.

Reported cause

A high reading of the crankcase vacuum is caused by a failing AOS/regulator, period.

Self healing AOS?

leak in the regulator diaphragm, and depending

No successful repair reported for this finding.

1
Identified cause
0
Suspected cause
0
Reported fixes
Read evidence and context
Discussions that report identifying a cause
1

0 original-poster resolution reports. Counts can overlap; they are not unique people or a success rate.

0 discussions have direct query context; 0 report a fix in that context. Other evidence may inherit the discussion’s subject.

Reported cause

As far as AOS failure causing intermittent readings, the #1 cause is a leak in the regulator diaphragm, and depending on the size of the leak will determine the effect on the Diaphragm Regulator Control.

Self healing AOS?
Coverage and how to read this overview

Counts describe captured discussions, not unique people or a diagnosis. Author identities are not reliably stored. Exact duplicate evidence is counted once across matching discussions; one discussion counts at most once per action/state. Multiple repairs reported together remain a combination. Suggestions and failed attempts do not establish a fix. Matches cover whole discussions and can include related faults, model variants and incomplete threads.

19 eligible posts · 0 unverified posts · 1 discussions match the subject in their title or opening post.

  • Rennlist: 1 discussions

0 evidence records excluded for query context · 0 excluded by outcome qualification · 0 adjusted by outcome qualification.

0 acknowledgements have no verified action link; they do not establish a repair result.

Generation: 20261026T113718Z · outcome-qualification-6. Deterministic extraction; no AI model inference. How we use sources

POST 1 / ORIGINAL POSTEROriginal post

So I have an electronic manometer and have been monitoring my AOS every few months. The first few times I tested it was well under 5”H2O. Then the next time it read a little under 7”. Someone suggested I change the battery and retest. Last time, after a new battery was installed, was back in November of last year and it reached nearly 9”. I’ve been putting replacement off, and then decided I’d wait for @Porschetech3 ’s UAOS. When I tested it on Friday after a 35 mile commute, it read 4.94”. I’m going to retest after my commute tomorrow. What could cause an AOS to fail, and then un-fail? Maybe I need to test the old fashioned way with a slack tube.

POST 2Original post

Mine failing cost me the engine.. Ya takes your chances..

POST 3Original post

Cars don't heal themselves. If you AOS showed signs of failing, it will not magically fix itself. I fit happened ones, it will happen again. Your car is trying to tell you something, make sure you listen.

POST 4Original post

Did you test under identical conditions? I.e. the same amount of driving and everything up to temp?

POST 5Original post

Mine is (Scott caught me again) all over the place and I'm not sure if my Manometer is even working properly.

POST 6Original post

Maybe you have an intermittent vacuum leak somewhere else in the system that causes erratic readings ??

POST 7Original post

Quotes source post: 16455588

I had to read this a couple of times. This is what came to mind, first...

POST 8Original post

Quotes source post: 16455682

There you go, using rational thought.

POST 9Original post

Quotes source post: 16455588

Maybe you should try a Ladyometer... it may treat you better

POST 10Original post

Quotes source posts: 16455693, 16455588

I hate it when that happens. I�ll go back to jackass mode now. There are little blue pills that can help with that...I mean I�ve been told!

POST 11Original post

Quotes source post: 16455725

Don't try to muscle in on my territory.

POST 12Original post

I agree that an intermittent issue would be more likely than self healing. Hopefully @Porschetech3 could chime in, or you could bring it up in his AOS Solution thread.

POST 13Original post

Quotes source post: 16455689

Yup, the m96 is loaded with mines!

POST 14Original post

Quotes source post: 16455682

That crossed my mind (see that Scott). Might be the old oil fill cap I used.

POST 15Original post

Quotes source post: 16455825

Or if you are accessing the site on your phone and using the tiny little "keypad", inserting an apostrophe is a pain in the ***.

POST 16Original post

Quotes source post: 16455834

Nope, early a.m. brain fart...

POST 17Original post

A high reading of the crankcase vacuum is caused by a failing AOS/regulator, period. An air leak of the crankcase( oil cap or fill tube bellows ect) will cause a "low" reading of crankcase vacuum, and also a lean air/fuel condition due to fresh air/oxygen ingestion. A vaccum/air leak on the intake manifold/lines will not effect crankcase vacuum (manometer reading), but will effect intake vacuum reading and cause lean air/fuel condition.. As far as the manometer being inaccurate, that is highly unlikely unless it's some dirt cheap China junk. As far as AOS failure causing intermittent readings, the #1 cause is a leak in the regulator diaphragm, and depending on the size of the leak will determine the effect on the Diaphragm Regulator Control. The Atmosphere port is very small on the factory design AOS and it only takes a very small leak in the diaphragm to effect the pressure on that side of the diaphragm. The diaphragm is rubber so the leak can and will vary in size, causing the pressure control to be unstable. A complete failure (big rip) in the rubber diaphragm will cause full manifold vacuum (400 inh2o) 29 inhg to be applied to the crankcase as is #1 cause of engine hydrolock.

POST 18Original post

Bruce , I am building you UAOS as we speak, and will be shipping it out tomorrow, with a "new reworked AOS", since your is failing it is high priority. Since these are Custom built, production is a little slow, but mostly due to backorder from Porsche Factory parts ( Auto Atlanta) like the hose I use and rework it to fit. Just waiting on the backordered hoses from Auto Atlanta, and rest of my Accumlator order to be printed by Schmit Proto to complete the other orders, then I will be ready to order another batch.

POST 19Original post

Quotes source post: 16456400

Another reason I love my DIY slack tube...as long as there is gravity, it reads correct.

This is a source reference. Confirm exact model applicability in the original material.