Rennlist

Climate control unit flashing

Add to repair workspace
Open repair workspace
Original source
11 captured repliesDiscussion pagination complete · Source accounts, not a confirmed diagnosis
THIS DISCUSSION / SOURCE-DERIVED OVERVIEW

Discussion summary

YOUR RESEARCHClimate control unit flashing

Leading reported evidence

Replace on my 04 996

Performed · outcome unconfirmed

No successful repair reported for this finding.

0
Reported fixes
0
Unsuccessful attempts
1
Discussions
Read evidence and context

Explicit resolution reports before identified causes, performed actions and suggestions. Within each level, matching component labels precede direct query mentions and inherited thread context; successful versus unsuccessful discussion counts, owner confirmations and independent discussion support determine order. This is not a probability of success.

Discussions that performed work without a confirmed outcome
1

0 original-poster resolution reports. Counts can overlap; they are not unique people or a success rate.

0 discussions have direct query context; 0 report a fix in that context. Other evidence may inherit the discussion’s subject.

Performed · outcome unconfirmed · Original poster

Had the climate control unit replaced on my 04 996.

Climate control unit flashing
Frequently discussed work

Disconnect battery right

No successful repair reported for this finding.

0
Reported fixes
0
Unsuccessful attempts
1
Discussions
Read evidence and context
Discussions that contain suggestions
1

0 original-poster resolution reports. Counts can overlap; they are not unique people or a success rate.

0 discussions have direct query context; 0 report a fix in that context. Other evidence may inherit the discussion’s subject.

Suggestion · Original poster

I can clear all the codes and reset by disconnecting the battery right?

Climate control unit flashing
Read full discussion summary

Leading evidence: 'Replace on my 04 996' (no explicit attributable resolution; this is a reported action or suggestion). Across 1 matching discussions, the most frequently mentioned possible cause is 'reset of the new unit' (1 discussions; 0 report identifying it and 1 suggest it). The most frequently discussed action is 'Disconnect battery right' (1 discussions). For that action, 0 discussions report a resolution and 0 report an unsuccessful attempt. No action has an explicit, attributable resolution report under the current rules. These are forum reports and suggestions, not a confirmed diagnosis.

Source reports, not a diagnosis or a success probability. Counts refer to discussions and can overlap.

Read captured replies

1 matching discussions · 11 captured posts examined · 0 partial discussions

Compare 4 other evidence results

Run ac system

Performed · outcome unconfirmed

No successful repair reported for this finding.

0
Reported fixes
0
Unsuccessful attempts
1
Discussions
Read evidence and context

Explicit resolution reports before identified causes, performed actions and suggestions. Within each level, matching component labels precede direct query mentions and inherited thread context; successful versus unsuccessful discussion counts, owner confirmations and independent discussion support determine order. This is not a probability of success.

Discussions that performed work without a confirmed outcome
1

0 original-poster resolution reports. Counts can overlap; they are not unique people or a success rate.

0 discussions have direct query context; 0 report a fix in that context. Other evidence may inherit the discussion’s subject.

Performed · outcome unconfirmed

Re-ran AC system test and flashing went away.

Climate control unit flashing

Run durametic and unit started flashing upon start up

Performed · outcome unconfirmed

No successful repair reported for this finding.

0
Reported fixes
0
Unsuccessful attempts
1
Discussions
Read evidence and context

Explicit resolution reports before identified causes, performed actions and suggestions. Within each level, matching component labels precede direct query mentions and inherited thread context; successful versus unsuccessful discussion counts, owner confirmations and independent discussion support determine order. This is not a probability of success.

Discussions that performed work without a confirmed outcome
1

0 original-poster resolution reports. Counts can overlap; they are not unique people or a success rate.

0 discussions have direct query context; 0 report a fix in that context. Other evidence may inherit the discussion’s subject.

Performed · outcome unconfirmed

Ran Durametic and unit started flashing upon start up.

Climate control unit flashing

Run full ranges like what's described above

Performed · outcome unconfirmed

No successful repair reported for this finding.

0
Reported fixes
0
Unsuccessful attempts
1
Discussions
Read evidence and context

Explicit resolution reports before identified causes, performed actions and suggestions. Within each level, matching component labels precede direct query mentions and inherited thread context; successful versus unsuccessful discussion counts, owner confirmations and independent discussion support determine order. This is not a probability of success.

Discussions that performed work without a confirmed outcome
1

0 original-poster resolution reports. Counts can overlap; they are not unique people or a success rate.

0 discussions have direct query context; 0 report a fix in that context. Other evidence may inherit the discussion’s subject.

Performed · outcome unconfirmed

During the test, all the display segments were turned on, the servos all ran full ranges like what's described above.

Climate control unit flashing

Run into this issue

Performed · outcome unconfirmed

No successful repair reported for this finding.

0
Reported fixes
0
Unsuccessful attempts
1
Discussions
Read evidence and context

Explicit resolution reports before identified causes, performed actions and suggestions. Within each level, matching component labels precede direct query mentions and inherited thread context; successful versus unsuccessful discussion counts, owner confirmations and independent discussion support determine order. This is not a probability of success.

Discussions that performed work without a confirmed outcome
1

0 original-poster resolution reports. Counts can overlap; they are not unique people or a success rate.

0 discussions have direct query context; 0 report a fix in that context. Other evidence may inherit the discussion’s subject.

Performed · outcome unconfirmed

Ran into this issue.

Climate control unit flashing
Frequently discussed actions (10)

These are separate views of the same evidence. Frequency alone does not establish a fix, and these counts must not be added together.

Disconnect battery right

No successful repair reported for this finding.

0
Reported fixes
0
Unsuccessful attempts
1
Discussions
Read evidence and context
Discussions that contain suggestions
1

0 original-poster resolution reports. Counts can overlap; they are not unique people or a success rate.

0 discussions have direct query context; 0 report a fix in that context. Other evidence may inherit the discussion’s subject.

Suggestion · Original poster

I can clear all the codes and reset by disconnecting the battery right?

Climate control unit flashing

Replace on my 04 996

No successful repair reported for this finding.

0
Reported fixes
0
Unsuccessful attempts
1
Discussions
Read evidence and context
Discussions that performed work without a confirmed outcome
1

0 original-poster resolution reports. Counts can overlap; they are not unique people or a success rate.

0 discussions have direct query context; 0 report a fix in that context. Other evidence may inherit the discussion’s subject.

Performed · outcome unconfirmed · Original poster

Had the climate control unit replaced on my 04 996.

Climate control unit flashing

Reset by

No successful repair reported for this finding.

0
Reported fixes
0
Unsuccessful attempts
1
Discussions
Read evidence and context
Discussions that contain suggestions
1

0 original-poster resolution reports. Counts can overlap; they are not unique people or a success rate.

0 discussions have direct query context; 0 report a fix in that context. Other evidence may inherit the discussion’s subject.

Suggestion · Original poster

I can clear all the codes and reset by disconnecting the battery right?

Climate control unit flashing

Reset of the new unit

No successful repair reported for this finding.

0
Reported fixes
0
Unsuccessful attempts
1
Discussions
Read evidence and context
Discussions that contain suggestions
1

0 original-poster resolution reports. Counts can overlap; they are not unique people or a success rate.

0 discussions have direct query context; 0 report a fix in that context. Other evidence may inherit the discussion’s subject.

Suggestion

If I'm not mistaken, this is due to the reset of the new unit.

Climate control unit flashing

Run a/c everything runs

No successful repair reported for this finding.

0
Reported fixes
0
Unsuccessful attempts
1
Discussions
Read evidence and context
Discussions that contain suggestions
1

0 original-poster resolution reports. Counts can overlap; they are not unique people or a success rate.

0 discussions have direct query context; 0 report a fix in that context. Other evidence may inherit the discussion’s subject.

Suggestion

I ran the system test...status bar shows completed, but then when I go to run the A/C everything runs for like a minute, compressor kicks on and then poof...blows the fuse in b10.

Climate control unit flashing

Run ac system

No successful repair reported for this finding.

0
Reported fixes
0
Unsuccessful attempts
1
Discussions
Read evidence and context
Discussions that performed work without a confirmed outcome
1

0 original-poster resolution reports. Counts can overlap; they are not unique people or a success rate.

0 discussions have direct query context; 0 report a fix in that context. Other evidence may inherit the discussion’s subject.

Performed · outcome unconfirmed

Re-ran AC system test and flashing went away.

Climate control unit flashing

Run durametic and unit started flashing upon start up

No successful repair reported for this finding.

0
Reported fixes
0
Unsuccessful attempts
1
Discussions
Read evidence and context
Discussions that performed work without a confirmed outcome
1

0 original-poster resolution reports. Counts can overlap; they are not unique people or a success rate.

0 discussions have direct query context; 0 report a fix in that context. Other evidence may inherit the discussion’s subject.

Performed · outcome unconfirmed

Ran Durametic and unit started flashing upon start up.

Climate control unit flashing

Run full ranges like what's described above

No successful repair reported for this finding.

0
Reported fixes
0
Unsuccessful attempts
1
Discussions
Read evidence and context
Discussions that performed work without a confirmed outcome
1

0 original-poster resolution reports. Counts can overlap; they are not unique people or a success rate.

0 discussions have direct query context; 0 report a fix in that context. Other evidence may inherit the discussion’s subject.

Performed · outcome unconfirmed

During the test, all the display segments were turned on, the servos all ran full ranges like what's described above.

Climate control unit flashing

Run into this issue

No successful repair reported for this finding.

0
Reported fixes
0
Unsuccessful attempts
1
Discussions
Read evidence and context
Discussions that performed work without a confirmed outcome
1

0 original-poster resolution reports. Counts can overlap; they are not unique people or a success rate.

0 discussions have direct query context; 0 report a fix in that context. Other evidence may inherit the discussion’s subject.

Performed · outcome unconfirmed

Ran into this issue.

Climate control unit flashing

Run system

No successful repair reported for this finding.

0
Reported fixes
0
Unsuccessful attempts
1
Discussions
Read evidence and context
Discussions that performed work without a confirmed outcome
1

0 original-poster resolution reports. Counts can overlap; they are not unique people or a success rate.

0 discussions have direct query context; 0 report a fix in that context. Other evidence may inherit the discussion’s subject.

Performed · outcome unconfirmed

I ran the system test...status bar shows completed, but then when I go to run the A/C everything runs for like a minute, compressor kicks on and then poof...blows the fuse in b10.

Climate control unit flashing
Reported and suspected causes (1)

These are separate views of the same evidence. Frequency alone does not establish a fix, and these counts must not be added together.

reset of the new unit

No successful repair reported for this finding.

0
Identified cause
1
Suspected cause
0
Reported fixes
Read evidence and context
Discussions that suspect a cause
1

0 original-poster resolution reports. Counts can overlap; they are not unique people or a success rate.

0 discussions have direct query context; 0 report a fix in that context. Other evidence may inherit the discussion’s subject.

Suspected cause

If I'm not mistaken, this is due to the reset of the new unit.

Climate control unit flashing
Coverage and how to read this overview

Counts describe captured discussions, not unique people or a diagnosis. Author identities are not reliably stored. Exact duplicate evidence is counted once across matching discussions; one discussion counts at most once per action/state. Multiple repairs reported together remain a combination. Suggestions and failed attempts do not establish a fix. Matches cover whole discussions and can include related faults, model variants and incomplete threads.

11 eligible posts · 0 unverified posts · 1 discussions match the subject in their title or opening post.

  • Rennlist: 1 discussions

0 evidence records excluded for query context · 0 excluded by outcome qualification · 0 adjusted by outcome qualification.

0 acknowledgements have no verified action link; they do not establish a repair result.

Generation: 20261026T091943Z · outcome-qualification-6. Deterministic extraction; no AI model inference. How we use sources

POST 1 / ORIGINAL POSTEROriginal post

Had the climate control unit replaced on my 04 996. The led's were bad. Now when I start the car up sometimes, not all the time, the led's flash a couple of times. Everything works fine after but I assume this is some type or error indication. Any ideas?

POST 2Original post

No worries. If I'm not mistaken, this is due to the reset of the new unit. Count the number of blinks each time. It should blink one time less every time the car is started. So eventually it will stop blinking.

POST 3 / ORIGINAL POSTEROriginal post

The unit is flashing 9 times. I turned on and off the car a number of times however it stays steady at 9.

POST 4Original post

Then it's something else. I believe you are correct that it's indicating some sort of error it has detected and the fault is still present. If you have a Durametric, you could retrieve the error code(s).

POST 5 / ORIGINAL POSTEROriginal post

Any other way to get error code? Seems like I should be able to push some combination on the climate control.

POST 6Original post

A possibility is the ECU may need to be reset to "identify" the new system. You might need PIWIS or PST2 to find the new system...

POST 7 / ORIGINAL POSTEROriginal post

Quotes source post: 11369983

Before I do something stupid let me check. I can clear all the codes and reset by disconnecting the battery right?

POST 8Original post

You need to do a system test to adapt the new unit.

POST 9Original post

This is too funny. I had the exact issue a few months back after I did the "System Test" using Durametric (the a/c system had no error codes detected by Durametric). During the test, all the display segments were turned on, the servos all ran full ranges like what's described above. After that, the ac display started flashing every time I start my car. I swear the ac display flashed less and less and eventually stopped flashing after a few wks or so. Last night I checked, it's flashing exactly 9 times like the OP. So I did the "System Test" using Durametric again but nothing changed. Still flashing. So is it possible somehow Durametric does not do the full test like PIWIS and PST2? Surely it tried and seemed to be doing the same tests. Or maybe it's contagious?

POST 10Original post

Same issue for me. Ran Durametic and unit started flashing upon start up. Read aomething on another forum that had porsche workshop instructions for AC system test. One instruction said �car must be on�. So I tried duramtric again with car ignition on and started. Re-ran AC system test and flashing went away. This was on a 2006 997 C4S.

POST 11Original post

Quotes source post: 15038181

Ran into this issue. flashing 9 times. I ran the system test...status bar shows completed, but then when I go to run the A/C everything runs for like a minute, compressor kicks on and then poof...blows the fuse in b10. I changed out my ignition switch this weekend....dont think I touched anything climate related. Anyone ever encounter any of this?

This is a source reference. Confirm exact model applicability in the original material.