fullymatted.
Back to search
Planet-9

P0155

Add to repair workspace
Open repair workspace
Original source
1 captured repliesPartial discussion capture · Source accounts, not a confirmed diagnosis
THIS DISCUSSION / SOURCE-DERIVED OVERVIEW

Discussion summary

YOUR RESEARCHP0155

Leading reported evidence

Set point

Suggestion or failed attempt

No successful repair reported for this finding.

0
Reported fixes
0
Unsuccessful attempts
1
Discussions
Read evidence and context

Explicit resolution reports before identified causes, performed actions and suggestions. Within each level, matching component labels precede direct query mentions and inherited thread context; successful versus unsuccessful discussion counts, owner confirmations and independent discussion support determine order. This is not a probability of success.

Discussions that contain suggestions
1

0 original-poster resolution reports. Counts can overlap; they are not unique people or a success rate.

0 discussions have direct query context; 0 report a fix in that context. Other evidence may inherit the discussion’s subject.

Suggestion

This can be used to discover discrepancies between the set point and

P0155
Read full discussion summary

Leading evidence: 'Set point' (no explicit attributable resolution; this is a reported action or suggestion). Across 1 matching discussions, The most frequently discussed action is 'Set point' (1 discussions). For that action, 0 discussions report a resolution and 0 report an unsuccessful attempt. No action has an explicit, attributable resolution report under the current rules. These are forum reports and suggestions, not a confirmed diagnosis.

Source reports, not a diagnosis or a success probability. Counts refer to discussions and can overlap.

Read captured replies

1 matching discussions · 1 captured posts examined · 1 partial discussions

Frequently discussed actions (1)

These are separate views of the same evidence. Frequency alone does not establish a fix, and these counts must not be added together.

Set point

No successful repair reported for this finding.

0
Reported fixes
0
Unsuccessful attempts
1
Discussions
Read evidence and context
Discussions that contain suggestions
1

0 original-poster resolution reports. Counts can overlap; they are not unique people or a success rate.

0 discussions have direct query context; 0 report a fix in that context. Other evidence may inherit the discussion’s subject.

Suggestion

This can be used to discover discrepancies between the set point and

P0155
Coverage and how to read this overview

Counts describe captured discussions, not unique people or a diagnosis. Author identities are not reliably stored. Exact duplicate evidence is counted once across matching discussions; one discussion counts at most once per action/state. Multiple repairs reported together remain a combination. Suggestions and failed attempts do not establish a fix. Matches cover whole discussions and can include related faults, model variants and incomplete threads.

1 eligible posts · 0 unverified posts · 1 discussions match the subject in their title or opening post.

  • Planet-9: 1 discussions

0 evidence records excluded for query context · 0 excluded by outcome qualification · 0 adjusted by outcome qualification.

0 acknowledgements have no verified action link; they do not establish a repair result.

Generation: 20261026T074343Z · outcome-qualification-6. Deterministic extraction; no AI model inference. How we use sources

POST 1Original post

O2 sensor heater, function NOTE The function checks the sensor temperature (by measuring the internal resistance of the Nernst cell) depending on the exhaust temperature. This can be used to discover discrepancies between the set point and actual temperature of the O2 sensor, from which a faulty heating control can be deduced. If the DME has detected a vehicle voltage > 16 V, fuel trim is also interrupted. Diagnostic conditions DME control unit power supply voltage (DME) 10 V … 16 V Exhaust temperature 300 °C (572 °F) ... 600 °C (1,112 °F) Time after engine starts > 200 s Intake air temperature > -7 °C (19 °F) No overrun No other driver fault of O2 sensor heater Possible fault causes Vehicle voltage > 16 V Connector corrosion Contact resistance in the lines O2 sensor faulty DME control unit faulty

This is a source reference. Confirm exact model applicability in the original material.