fullymatted.
Back to search
Planet-9

P0016

Add to repair workspace
Open repair workspace
Original source
1 captured repliesPartial discussion capture · Source accounts, not a confirmed diagnosis
THIS DISCUSSION / SOURCE-DERIVED OVERVIEW

Discussion summary

YOUR RESEARCHP0016

Leading reported evidence

Set incorrectly

Suggestion or failed attempt

No successful repair reported for this finding.

0
Reported fixes
0
Unsuccessful attempts
1
Discussions
Read evidence and context

Explicit resolution reports before identified causes, performed actions and suggestions. Within each level, matching component labels precede direct query mentions and inherited thread context; successful versus unsuccessful discussion counts, owner confirmations and independent discussion support determine order. This is not a probability of success.

Discussions that contain suggestions
1

0 original-poster resolution reports. Counts can overlap; they are not unique people or a success rate.

0 discussions have direct query context; 0 report a fix in that context. Other evidence may inherit the discussion’s subject.

Suggestion

Timing set incorrectly

P0016
Read full discussion summary

Leading evidence: 'Set incorrectly' (no explicit attributable resolution; this is a reported action or suggestion). Across 1 matching discussions, The most frequently discussed action is 'Set incorrectly' (1 discussions). For that action, 0 discussions report a resolution and 0 report an unsuccessful attempt. No action has an explicit, attributable resolution report under the current rules. These are forum reports and suggestions, not a confirmed diagnosis.

Source reports, not a diagnosis or a success probability. Counts refer to discussions and can overlap.

Read captured replies

1 matching discussions · 1 captured posts examined · 1 partial discussions

Frequently discussed actions (1)

These are separate views of the same evidence. Frequency alone does not establish a fix, and these counts must not be added together.

Set incorrectly

No successful repair reported for this finding.

0
Reported fixes
0
Unsuccessful attempts
1
Discussions
Read evidence and context
Discussions that contain suggestions
1

0 original-poster resolution reports. Counts can overlap; they are not unique people or a success rate.

0 discussions have direct query context; 0 report a fix in that context. Other evidence may inherit the discussion’s subject.

Suggestion

Timing set incorrectly

P0016
Coverage and how to read this overview

Counts describe captured discussions, not unique people or a diagnosis. Author identities are not reliably stored. Exact duplicate evidence is counted once across matching discussions; one discussion counts at most once per action/state. Multiple repairs reported together remain a combination. Suggestions and failed attempts do not establish a fix. Matches cover whole discussions and can include related faults, model variants and incomplete threads.

1 eligible posts · 0 unverified posts · 1 discussions match the subject in their title or opening post.

  • Planet-9: 1 discussions

0 evidence records excluded for query context · 0 excluded by outcome qualification · 0 adjusted by outcome qualification.

0 acknowledgements have no verified action link; they do not establish a repair result.

Generation: 20261026T172408Z · outcome-qualification-6. Deterministic extraction; no AI model inference. How we use sources

POST 1Original post

Position of crankshaft in relation to intake camshaft NOTE This fault is entered if there is a permanent deviation from the nominal value of 10° camshaft angle. Diagnostic conditions: Battery positive voltage 10 ... 16 V Engine idling Camshaft adaptation has taken place No fault in camshaft sensor No fault in crankshaft sensor Possible fault causes: Camshaft sensor faulty (internal phase shift) Solenoid valve for camshaft adjustment soiled (does not close fully) Timing set incorrectly

This is a source reference. Confirm exact model applicability in the original material.