11 captured repliesDiscussion pagination complete · Source accounts, not a confirmed diagnosis
THIS DISCUSSION / SOURCE-DERIVED OVERVIEW
Discussion summary
YOUR RESEARCHWeird HVAC Issue - 986 Forum - The Community for Porsche Boxster & Cayman Owners
Leading reported evidence
Check voltage at one of the the electric plugs
Performed · outcome unconfirmed
No successful repair reported for this finding.
0
Reported fixes
0
Unsuccessful attempts
1
Discussions
Read evidence and context
Explicit resolution reports before identified causes, performed actions and suggestions. Within each level, matching component labels precede direct query mentions and inherited thread context; successful versus unsuccessful discussion counts, owner confirmations and independent discussion support determine order. This is not a probability of success.
Discussions that performed work without a confirmed outcome
1
0 original-poster resolution reports. Counts can overlap; they are not unique people or a success rate.
0 discussions have direct query context; 0 report a fix in that context. Other evidence may inherit the discussion’s subject.
Performed · outcome unconfirmed · Original poster
- Checked the voltage at one of the the electric plugs for the valve motors and the voltage continues to fluctuate rapidly.
Weird HVAC Issue - 986 Forum - The Community for Porsche Boxster & Cayman Owners
Read full discussion summary
Leading evidence: 'Check voltage at one of the the electric plugs' (no explicit attributable resolution; this is a reported action or suggestion). Across 1 matching discussions, The most frequently discussed action is 'Check foam pieces' (1 discussions). For that action, 0 discussions report a resolution and 0 report an unsuccessful attempt. No action has an explicit, attributable resolution report under the current rules. These are forum reports and suggestions, not a confirmed diagnosis.
Source reports, not a diagnosis or a success probability. Counts refer to discussions and can overlap.
Explicit resolution reports before identified causes, performed actions and suggestions. Within each level, matching component labels precede direct query mentions and inherited thread context; successful versus unsuccessful discussion counts, owner confirmations and independent discussion support determine order. This is not a probability of success.
Discussions that contain suggestions
1
0 original-poster resolution reports. Counts can overlap; they are not unique people or a success rate.
0 discussions have direct query context; 0 report a fix in that context. Other evidence may inherit the discussion’s subject.
Suggestion · Original poster
- Checked for foam pieces that could block something in the airpath.
Weird HVAC Issue - 986 Forum - The Community for Porsche Boxster & Cayman Owners
Check fuses, relays and wires based
Suggestion or failed attempt
No successful repair reported for this finding.
0
Reported fixes
0
Unsuccessful attempts
1
Discussions
Read evidence and context
Explicit resolution reports before identified causes, performed actions and suggestions. Within each level, matching component labels precede direct query mentions and inherited thread context; successful versus unsuccessful discussion counts, owner confirmations and independent discussion support determine order. This is not a probability of success.
Discussions that contain suggestions
1
0 original-poster resolution reports. Counts can overlap; they are not unique people or a success rate.
0 discussions have direct query context; 0 report a fix in that context. Other evidence may inherit the discussion’s subject.
Suggestion · Original poster
I will double check the fuses, relays and wires based on your feedback.
Weird HVAC Issue - 986 Forum - The Community for Porsche Boxster & Cayman Owners
Check resistance
Suggestion or failed attempt
No successful repair reported for this finding.
0
Reported fixes
0
Unsuccessful attempts
1
Discussions
Read evidence and context
Explicit resolution reports before identified causes, performed actions and suggestions. Within each level, matching component labels precede direct query mentions and inherited thread context; successful versus unsuccessful discussion counts, owner confirmations and independent discussion support determine order. This is not a probability of success.
Discussions that contain suggestions
1
0 original-poster resolution reports. Counts can overlap; they are not unique people or a success rate.
0 discussions have direct query context; 0 report a fix in that context. Other evidence may inherit the discussion’s subject.
Suggestion
So if your doing continuity tests you also need to check the resistance on the wire..
Weird HVAC Issue - 986 Forum - The Community for Porsche Boxster & Cayman Owners
Replace associated relays
Suggestion or failed attempt
No successful repair reported for this finding.
0
Reported fixes
0
Unsuccessful attempts
1
Discussions
Read evidence and context
Explicit resolution reports before identified causes, performed actions and suggestions. Within each level, matching component labels precede direct query mentions and inherited thread context; successful versus unsuccessful discussion counts, owner confirmations and independent discussion support determine order. This is not a probability of success.
Discussions that contain suggestions
1
0 original-poster resolution reports. Counts can overlap; they are not unique people or a success rate.
0 discussions have direct query context; 0 report a fix in that context. Other evidence may inherit the discussion’s subject.
Weird HVAC Issue - 986 Forum - The Community for Porsche Boxster & Cayman Owners
Replace color
No successful repair reported for this finding.
0
Reported fixes
0
Unsuccessful attempts
1
Discussions
Read evidence and context
Discussions that contain suggestions
1
0 original-poster resolution reports. Counts can overlap; they are not unique people or a success rate.
0 discussions have direct query context; 0 report a fix in that context. Other evidence may inherit the discussion’s subject.
Suggestion
It also looks like B13 has a connector where the wire changes color from yel/blu to orn/grn...so you need to check that connection as well as everything along that wire.
Weird HVAC Issue - 986 Forum - The Community for Porsche Boxster & Cayman Owners
Use durametric
No successful repair reported for this finding.
0
Reported fixes
0
Unsuccessful attempts
1
Discussions
Read evidence and context
Discussions that contain suggestions
1
0 original-poster resolution reports. Counts can overlap; they are not unique people or a success rate.
0 discussions have direct query context; 0 report a fix in that context. Other evidence may inherit the discussion’s subject.
Suggestion · Original poster
AC now engages when I activate it using Durametric, but the snowflake icon still does not come on when I try to turn on AC on the climate control unit.
Weird HVAC Issue - 986 Forum - The Community for Porsche Boxster & Cayman Owners
Coverage and how to read this overview
Counts describe captured discussions, not unique people or a diagnosis. Author identities are not reliably stored. Exact duplicate evidence is counted once across matching discussions; one discussion counts at most once per action/state. Multiple repairs reported together remain a combination. Suggestions and failed attempts do not establish a fix. Matches cover whole discussions and can include related faults, model variants and incomplete threads.
11 eligible posts · 0 unverified posts · 1 discussions match the subject in their title or opening post.
986Forum: 1 discussions
0 evidence records excluded for query context · 1 excluded by outcome qualification · 0 adjusted by outcome qualification.
0 acknowledgements have no verified action link; they do not establish a repair result.
Generation: 20261027T165639Z · outcome-qualification-6. Deterministic extraction; no AI model inference. How we use sources
Hello fellow 986 owners.
Ever since I purchased my 2000 986 S, its HVAC has been behaving weirdly. By weird, I mean that the blower doesn't spin and there is no air output. I can control everything on the climate control unit, except for the AC (AC icon doesn't come on the screen when I press the snowflake button). The four electric flaps/valves (part number for one of them: 996 573 917 00) move erratically and make noises. The bar indicators on the climate control unit for fan power change on its own even in "Manuell" mode.
Here's what I did so far:
- Replaced parts with tested and functioning units:
Blower motor
Final stage ("resistor")
Climate control unit
Actuation heating relay (#18 on top of the fuse box)
Ignition switch
- Checked the voltage at one of the the electric plugs for the valve motors and the voltage continues to fluctuate rapidly. All four valves work without issues when 12v is applied to them at the motor connectors in both directions.
- Tested continuity among the electric connectors of climate control unit, the blower motor, resistor, and the four flaps. All connections are fine indicating no broken wires.
- Confirmed there are no broken fuses (under the driver side).
- Checked for foam pieces that could block something in the airpath. Surprisingly, the foam pads on the trap doors are intact.
- Noticed that the AC relay is missing so I ordered one (trunk relay box #4). This probably explains the AC not turning on, not sure if it can be the cause of all the other behaviors, especially looking at the AC wiring diagram attached.
Is there anything I missed? Anyone had a similar issue?
Thank you for your help.
It looks like you've done all of the tricks that I would have tried. How about the diagnostics that Boxster Steve suggests in this thread:
http://986forum.com/forums/boxster-general-discussions/51702-using-c-display-oil-temp.html
Thank you for the suggestion. I tried it when I saw the post, but it unfortunately did not work on my vehicle. I hear that the earlier MY cars have better chance of it working.
Received the AC relay today and plugged it in.. AC now engages when I activate it using Durametric, but the snowflake icon still does not come on when I try to turn on AC on the climate control unit. No behavior changes on the HVAC unit.
What is voltage reading at B13 supposed to be? It seems to be the idle period signal from the cluster, and it rapidly fluctuates between 2 and 9.7 volts. I think this may be related to the symptom. If anyone knows what's the reading supposed to be, I'd really appreciate it.
Fluctuating voltage....
I would say you have a bad ground or a broken wire.
Or possibly a faulty relay
Continuity testing is not that reliable at telling you the wire is sound.... this is why..
Wires are made up of multiple strands it only takes one strand in that wire to show continuity.
The rest of the strands in the wire can be broken and it will still show continuity.
But the circuit will not function correctly because there is to much resistance in the broken strands for the current to flow.
So if your doing continuity tests you also need to check the resistance on the wire..
You say all the fuses are good how did you check them?
did you check that they are getting power to the power side of the fuse?
In the schematic you linked it shows five fuses at the top right on the first page.
four are hot all the time one is only hot with key on.
There are also two fuses shown at the top of page two
If you have not done so....
You need to test to make sure you have power on the hot side of the fuses.
Find and test or replace associated relays.
At the bottom of page one it show the ground point for the system you need to check that and make sure things are clean and tight.
Those are the things I would start with.
Thank you for the suggestion, blue62. I will double check the fuses, relays and wires based on your feedback.
Based on the fact the instrument cluster is sending fluctuating signal (received by the climate control at B13 wire), I guess I should expand my search to include the instrument cluster system as well.
Yes make sure your ground point is good as well as the ground wire and it's connection point at terminal 31. It also looks like B13 has a connector where the wire changes color from yel/blu to orn/grn...so you need to check that connection as well as everything along that wire.
This is a source reference. Confirm exact model applicability in the original material.