Single Row Pro IMS Retrofit Installation Manual — LN Engineering / PAGE 29
STEP STEP · 33 34
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
STEP STEP
33 34
Using a wrench and a flat-blade screwdriver, install Torque the IMS flange center nut to 10Nm
IMS flange center stud nut. Do not over-tighten. (7.5ft-lb) and apply wicking grade Loctite to
exposed threads.
INSTALLATIONINSTALLATIONMANUALMANUAL PAGE 26
This is a source reference. Confirm exact model applicability in the original material.