996 Turbo diagnostic manual — Turbo applicability only / PAGE 371

Air conditioning H01, H02 911 Turbo (996)80 · Work instruction Disp

Add to repair workspace
Open repair workspace
Open full manual Original source
Original manual page 371
Read extracted page text

OCR can contain errors. Check the original page image for exact wording, warnings and specifications.

Air conditioning H01, H02 911 Turbo (996)80 Work instruction Display OK If not OK 4 Check wiring between air- ♦Measure resistance between < 5Ω Repair wiring har- conditioning system regu- plug B on the air-conditioning ⇒ Step 6 ness lator and temperature system regulator pin 5 and plug → End sensor for interruption on outside temperature sensor pin 1 ♦Measure resistance between plug B on the air-conditioning system regulator pin 9 and plug on outside temperature sensor pin 2 5 ♦Replace temperature sensor → End 6 ♦Replace air-conditioning system regulator → End 80-7 page 2 8001 Fault code 21 21xxxh02 Printed in Germany – 15, 2001

This is a source reference. Confirm exact model applicability in the original material.