996 Turbo diagnostic manual — Turbo applicability only / PAGE 988
Alarm system I 48 911 Turbo (996)96 · them to the new control module. In this way, the hand-held transmit-
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
Alarm system I 48 911 Turbo (996)96
them to the new control module. In this way, the hand-held transmit-
ters (remote controls and transponders) can be retained. In other
words, it is not necessary to change the hand-held transmitter when
replacing the alarm system control module.
Requirements
• Communication can be set up between the PST2 and alarm sys-
tem control module.
• The remote controls and transponders are correct and func-
tional.
Note!
♦When the remote control is read out and transferred, only the
remote control data are read out and transferred.
♦The transponder of the individual keys must be adapted to the
control module. Four positions are available for this purpose in
menu item "Transponder key". This function is described from
step 19 onward.
Work preparation
The following information is required from the IPAS for reading out
and transferring remote controls:
♦Key learning code
♦Immobilizer code
Procedure
1. Connect PST2 to the data link connector, and switch on the
ignition.
2. Switch on the PST 2, select vehicle type 911 (996) and start
the automatic control module search with the double arrow key
>> .
3. After a brief search, the PST2 reports: "Fault memory reading
completed".
4. Select alarm system control module and press the double
arrow key >> .
5. Select "Learning function" in the menu and press the double
arrow key >> .
6. Select menu item ’Read out remote control’ and press the dou-
ble arrow key >> .
96-5 page 12 9601 Control module function
sgf_xi48 Printed in Germany – 4, 2001
This is a source reference. Confirm exact model applicability in the original material.